TECHNICAL DATA48 XES SYNERGIX 8850 PRINTER OPERATOR MANUALThe XES Synergix 8850 Printer will operate within thespecifications indicated in the table below for the respectivemarkets. Current limit will be set as part of the installationprocedure. The printer is not sensitive to the AC power servicefrequency and can operate at either 50hz or 60hz.Table 6. Operating powerMarket area AC power serviceratingMaximum currentconsumptionFirst Print Out TimeUS/Canada 115V @ 20A208V – 240V @ 20A208V – 240V @ 15A17.6A17.6A13.2ALess than 5 minutes*Less than 3 minutesLess than 4 minutesEuropean Operations -Common Market230V – 240V @ 16A 16.0A Less than 3 minutesUnited Kingdom 230V – 240V @ 13A 13.0A Less than 3.5 minutesSwitzerland 220V @ 10A 10.0A Less than 5 minutes*Central/South America 220V – 240V @ 20A 15A Less than 3 minutes*Continuous operation at the rate of 10 "D" prints per minute cannot be assured at this power service.The table below shows maximum print engine throughput in printsper minute. It assumes continuous printing from a single roll withno AC power limitation.Table 7. Maximum prints per minuteUS Europe/Central and South AmericaPortrait Landscape Portrait LandscapeN/A A = 23 N/A A4 = 24B = 13 B = 18 A3 = 13 A3 = 18C = 10 C = 13 A2 = 10 A2 = 13D = 7 D = 10 A1 = 7 A1 = 10E = 5 N/A A0 = 5 N/A