Xantrex RV Series Inverter/Charger Ownerís Manual17Connection of Grounding and Battery SystemsThe following diagram outlines proper connections for the RV Series inverter/chargers. Severalpoints of caution are:• DO NOT connect the battery negative (-) terminal to the vehicle chassis ground.• DO NOT connect the DC load negative to the battery negative (-). Connect only to the chassisground terminal on the inverter or to the vehicle chassis.+ñ+ ññ+G RV SeriesInverterDC LoadDistribution PanelBatteryInternal shunt connectionOptionalVehicle chassisVehicle chassisground (green)Connect DC loads to VehicleChassis or optionally to theInverterís Vehicle Chassis GroundTerminal (Green). Do not connectDC loads to battery negative (-)Do NOT connect batterynegative to vehicle chassisor vehicle chassis ground.Terminal connection tochassis ground is madeinside the inverter.