Features975-0411-01-01 1–5This guide for use by qualified installers onlyDC PanelFigure 1-2 DC PanelFeature Description1 Chassis Ground Lug connects to vehicle chassis.2 Ventilation Opening and Fan Assembly must not be obstructed forthe proper operation of the inverter. Refer to “Choosing anAppropriate Location and Mounting Orientation” on page 2–4 forinstallation clearances and orientation.3 Negative (–) DC Input Terminal connects to one end of thenegative battery cable. The other end of the negative battery cable isconnected to the negative terminal of the battery.4 Positive (+) DC Input Terminal connects to one end of the positivebattery cable. The other end of the positive battery cable isconnected to the positive terminal of the battery.5 Serial number of your inverter.DANGER: This unit employscompo-nents that tend to producearcs or sparks.Risk of fire and explosion– Do not installnear batteries, in machinery space, orarea in which ignition-protectedequipment is required. Shock Hazard –Do not open. No serviceable parts inside.INPUT: 12 Vdc (nominal),520 A (5 min. max.) / 415 A (cont.)OUTPUT: 120 Vac / 60 Hz5 kW / 41 A (5 min max.)4 kW / 33 A (continuous)CHASSIS GNDSerial No.BATTERYNEG.BATTERYPOS.WARNING: Shock,energy, and fire hazards. Readmanualbeforeinstallingor using.To preventfire, do not coverorobstruct ventilationopenings. Do not mount in zero-clearancecompartment. Overheatingmay result. Do not expose to rain orspray. Use GroundFault CircuitInterruptersonly as specifiedin the manualssuppliedwith this unit. Othertypesmay fail to operatewhen connected to this unit.Ensure proper grounding.Total harmonic distortion is 38%;maximum single harmonic is 32%.Patents PendingDesigned in Canada byXantrex / Assembled in China12345