DP224/6 Operators Manual Page 35AES / EBU Sub-MenuConnection of AES/EBU signals is via the existing rear panel XLR connectors.With the AES/EBU option fitted, AES Receive and Diagnostic modes are provided.Routing OptionsSelects the input source – either analogue or digital, and similarly the output source,again either analogue or digital.AES DiagnosticsReports validity flag, clock speed and errors present in the incoming AES digital signal.AES / EBU ConnectionsThe AES/EBU digital signal is a stereo data stream, and so only one input XLR andthree output XLRs are used for the digital interface.The connections are as follows:Input A - Analogue Input at all timesInput B - Switchable between digital (stereo) input and analogue inputOutput 1 - Switchable between digital out (for channels 1 & 2) and analogue out 1Output 2 - Switchable between digital out (for channels 3 & 4) and analogue out 2Output 3 - Switchable between digital out (for channels 5 & 6) and analogue out 3Output 4 - Analogue output 4 onlyOutput 5 - Analogue output 5 onlyOutput 6 - Analogue output 6 only