Electric DryerPRODUCT MODEL NUMBERS OVERALL DIMENSIONSWED6200S, WED6400S, WED6600V,WED6600W, WED7300X, WED7400X,WED7600X, WED7800XElectrical: This dryer requires a 3 or 4 wire, singlephase, 120/240 volt, 60 Hz., AC only electricalsupply (or 3 or 4 wire, 120/208 volt electrical supply,if specified on the serial/rating plate) on a separate30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connectto an individual branch circuit. Do not have a fuse in theneutral or grounding circuit.Exhaust venting: Exhaust your dryer to the outside.4" (102 mm) diameter vent is required. Rigid or flexiblemetal exhaust vent must be used. Do not use plasticor metal foil vent. Exhaust hood must be at least12" (305 mm) from the ground or any object thatmay be in the path of the exhaust.Exhaust hood styles:Vent System Chart:Dryer dimensionsSelect the route that will provide the straightest and mostdirect path outdoors. Plan the installation to use the fewestnumber of elbows and turns. Use the fewest 90° turnspossible. Do not use vent runs longer than specified invent length chart. Determine the number of elbows youwill need.Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installationour products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice.Ref. W10267633A04/2010For closet installation, with a door, the minimum ventilation openings in the topand bottom of the door are required. Louvered doors with equivalent air ventilationopenings are acceptable.For cabinet installation, with a door, the minimum ventilation openings in the top arerequired.NOTE: Side and bottom exhaust installations have a 90°turn inside the dryer. To determine maximum exhaust length,add one 90° turn to the chart.4"(102 mm)4"(102 mm)BA4"(102 mm)2½"(64 mm)CRecommended styles:A. Louvered hoodB. Box hoodAcceptable styles:C. Angled hoodNumber 90ºelbowsType of vent Box /louveredhoodsAngledhoods0 Rigid metal 64 ft. (20 m) 58ft. (17.7 m)1 Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)2 Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)3 Rigid metal 35 ft. (10.7 m) 29 ft. (8.8 m)4 Rigid metal 27 ft. (8.2 m) 21 ft. (6.4 m)Minimum required spacing29"(737 mm)221 /4 "(565 mm)291/4 "(743 mm)431/ 2"(1105 mm)14" máx.*(356 mm)29"(737 mm)5"(127 mm)1"(25 mm)1"(25 mm)18"*(457 mm)3"*(76 mm)3"*(76 mm)291/4 "(743 mm)48" 2*(310 cm2)24" 2*(155 cm2)RecessedareaSide view- closetor confined area Closet door withvents*Required spacingNOTE: Most installations require minimum 5" (127 mm) clearance for exhaust vent withelbow. See “Venting Requirements.”