®30" Freestanding Gas RangePRODUCT MODEL NUMBERS OVERALL DIMENSIONSCABINET OPENING DIMENSIONSGS395LEGB/Q/TGS395LEHSGS460LEKB/Q/TGS465LEKB/S/Q/TGS475LEKSSF195LEKB/Q/TSF356BEKB/Q/V/WSF357PEKQ/T/V/WSF365PEGN/Q/T/WSF367LEKB/Q/T/V/WSF367LEGWSF367LEHWSF369LEKQ/TSF377PEGB/N/T/V/W/ZSF379LEKB/Q/TSF380LEKQ/TSF385PEGB/N/Q/T/W/ZSF387LEGWSF387LEKB/Q/TSF389LEKQ/TBecause Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specifications without notice.Dimensions are for planning purposes only. For complete details, see InstallationInstructions packed with product. Specifications subject to change without notice.*** Note: 24" min. when bottom of wood or metal cabinetis protected by not less than 1/4" flame retardantmillboard covered with not less than No. 28 MSGsheet steel, 0.015" stainless steel, 0.024" aluminum or0.020" copper.30" min. clearance between the top of the cookingplatform and the bottom of an unprotected wood ormetal cabinet.Contact a qualified floor coveringinstaller to check that the floorcovering can withstand at least200˚F.Use an insulated pad or 1/4"plywood under range if installingrange over carpeting.For minimumclearance to top ofcooktop, see Note.***Do Not pinch the power supply cordbetween the range and the wall.Do Not seal the range to the sidecabinets.2" min.countertopspace to sidewall or othercombustiblematerialThis shaded area recommendedfor installation of rigid gas pipe.Flexible gas pipe and electricaloutlet are recommended in eithershaded area.18" min.clearance uppercabinet tocountertop13" max. uppercabinet depthIf cabinet depth is greater than 24",oven frame must extend beyondcabinet fronts by 1/2" min.30-1/8" openingwidth30" min. cabinetopening width8"4-1/2"4-1/2"2"2"17"17"8"Gas supply: Use 3/4" rigid pipe gas supply lineto the range location. A smaller size pipe on longruns may result in insufficient gas supply. WithL.P. gas, piping or tubing size can be 1/2"minimum. If local codes permit, it isrecommended that new flexible metal tubing,design-certified by AGA or CSA, 4-5 feet long,1/2-inch or 3/4-inch I.D., be used for connectingthe range to the rigid gas supply line. A 1/2" malepipe thread is needed for connection to pressureregulator female pipe threads. An individualmanual shutoff valve must be located in the sameroom, but external to the range.Electrical: A 120-volt, 60-Hz, AC-only,10-ampere, electrical supply fused on both sidesof the line. A separate circuit is recommended. Atime-delay fuse or circuit breaker is recommended.8 8 829-7/8" width46-7/8"overallheight25"36"cooktopheight27-1/8" depthwith handleRef. 8273170 Rev. A03-25-02