Whirlpool EGY60 Instruction Sheet
INSTRUCTION SHEETfor Compressor Start Device Kit for use onTop Mount Refrigerators withEGY60, EGY70 & EMU60 Type Compressors Only1. Pull the refrigerator away from the wall; make sure to protectthe floor from any damage.2. Unplug refrigerator or disconnect power.3. On the rear of the refrigerator, remove the screws holdingthe rear compartment cover in place. Remove the rearcover. Set the screws and rear cover aside for reuse later.(See Figure 1.)WARNINGElectrical Shock HazardDisconnect power before servicing.Failure to do so can result in deathor electrical shock.Replace all parts and panels beforeoperating.5. Identify the compressor type. See Figure 2.Kit Contains:1 Instruction Sheet1 PTC Start Relay2 Overloads1 Wire Jumper1 Terminal Cover1 Electrical CoverTools Needed:1 ¼” Nut Driver1 Pocket Standard ScrewdriverFIGURE 14. Remove the cover and all of the electrical componentsfrom the compressor; pull them straight off of the compressor.Disconnect from wire harness.© Whirlpool Corporation 2006(All Rights Reserved)FIGURE 2Instruction Sheet 8201770 5/06EXAMPLE OF COMPRESSORTYPE NUMBERNote: Some models may have a plastic tie strap aroundthe PTC relay. Remove and discard the strap. |