24”(61 cm)**34”(86.4 cm)min* 4”(10.2 cm)3”(7.6 cm)24”(61 cm)1-3/4”(4.4 cm)1-3/4”(4.4 cm)Check that all surfaceshave no protrusions that wouldprevent dishwasher installation.10-1/2”(26.7 cm)2”(5.1 cm)2-1/2”(6.4 cm)6-3/4”(17.2 cm)6-1/4”(15.9 cm) ClearAreaPRODUCT DIMENSIONSCABINET CUTOUT DIMENSIONSUndercounter Dishwasher®PRODUCT MODEL NUMBERSDU1055XTVDU1100XTPDU1101XTPDU1145XTPDU1148XTPGU2275XTVGU2300XTVGU2475XTVGU2800XTVElectrical Requirements: 120-volt, 60-Hz, AC-only, 15- or20-amp. fuesd electrical supply. Copper wire only. A time-delay fuse or circuit breaker and separate circuit isrecommended.If direct wiring dishwasher: Use flexible, armored or non-metallic, sheathed copper wire with grounding wire thatmeets the wiring requirements for your home and localcodes and ordinances.Use a U.L.-listed or CSA-approved conduit connector.If connecting dishwasher with a power supply cord: UsePower Supply Cord Kit (Part No. 4317824) marked for usewith dishwashers. Follow the kit instructions for installingthe power supply cord.Power supply cord must plug into a grounded three-prong,outlet, located in the cabinet next to the dishwasheropening. Outlet must meet all local codes and ordinances.Water Supply Requirements: A hot water line with 20 to120 psi (138 to 862 kPa) water pressure. Watertemperature must be 120°F (49°C) water at dishwasher.Use 3/8" O.D. copper tubing with compression fitting orflexible braided water supply line (1/2" minimum plastictubing is not recommended). Use a 90° elbow with 3/8"N.P.T. external pipe threads on one end. Do not solderwithin 6" (15.2 cm) from water inlet valve.Drain Requirements: A new drain hose is supplied withyour dishwasher. If this is not long enough, use a new drainhose with a maximum length of 12' (3.7 m) (Part No.3385556) that meets all current AHAM/IAPMO teststandards, is resistant to heat and detergent, and fits the 1"(2.5 cm) drain connector of the dishwasher.Make sure to connect the drain hose to waste tee ordisposer inlet above drain trap in house plumbing and 20"(50.8 cm) minimum above the floor. It is recommendedthat the drain hose either be looped up and securelyfastened to the underside of the counter, or be connected toan air gap.Make sure to use an air gapif the drain hose isconnected to houseplumbing lower than 20"(50.8 cm) above subfloor orfloor.Use 1/2" (1.3 cm) minimumI.D. drain line fittings.If required, the air gapshould be installed inaccordance with the air gap installation instructions. Whenconnecting the air gap a rubber hose (not provided) will beneeded to connect to the waste tee or disposer unit.Because Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specifications without notice.Dimensions are for planning purposes only. For complete details, see InstallationInstructions packed with product. Specifications subject to change without notice.Ref. W10142914 Rev B2-16-09air gap3/4”(1.9 cm)**Insulation maybe compressed.(not used on all models)24-1/2”(62.2 cm)25-1/4”(64.1 cm)23-7/8”(60.6 cm)21”(53.3 cm)33-7/8”(86 cm) min.with wheelsremovedCorner locations require a 2" (5.1 cm) minimum clearance between the side of the dishwasherdoor and the wall or cabinet.NOTE: Shaded area of cabinet walls show whereutility connections may be installed.*Measured from the lowest point on the undersideof countertop. May be reduced to 33-7/8” (86 cm)by removing wheels from dishwasher.**Minimum, measured from narrowest point of opening.