Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Declaration of conformity
- Warranty
- Exceptions
- When you unpack your pump
- Optional accessories
- Information for returning pumps
- Safety notes
- Pump specifications
- Standards (AC mains power supply)
- Standards (12-24V DC power supply)
- Dimensions
- Weights
- Good pump installation practice
- Do's and do not's
- Connecting to a power supply
- DC power supply option
- Start-up check list
- Automatic control wiring - Universal, Universal+ and Remote models without relay modules
- Input pin assignments at the pump
- Output pin assignments at the pump
- Optional output lead
- Module: cover removal and refitting
- Wiring up the terminal connectors
- V relay module pcb connectors
- V relay module pcb connectors
- PROFIBUS control wiring
- Pin assignments at the pump
- Switching on (Manual, PROFIBUS, Universal and Universal+)
- Switching the pump on in subsequent power cycles (Manual, PROFIBUS Universal and Universal+ only)
- Switching on (Remote)
- Pump operation
- Manual mode (Manual, PROFIBUS, Universal and Universal+ only)
- PROFIBUS mode(PROFIBUS only)
- Assigning the PROFIBUS station address at the pump
- PROFIBUS communication errors
- PROFIBUS GSD file
- User Parameter Data
- PROFIBUS data exchange
- Device-related diagnostic data
- Flow calibration mode (Manual, PROFIBUS, Universal and Universal+ only)
- Analog 4-20mA mode (Universal and Universal+ only)
- Calibrate the pump for 4-20mA control (Universal+ only)
- Contact Mode (All Universal and Universal+ models except 110V relay versions)
- Contact operating mode (All Universal and Universal+ models except 110V relay versions)
- Fluid recovery mode (Manual, PROFIBUS, Universal and Universal+ only)
- Remote fluid recovery (Universal and Universal+ models without relay modules)
- Main menu (Manual, PROFIBUS, Universal and Universal+ only)
- Fluid level monitor (Manual, PROFIBUS, Universal and Universal+ only)
- Security settings (Manual, PROFIBUS, Universal and Universal+ only)
- General settings (Manual, PROFIBUS, Universal and Universal+ only)
- MODE menu (Manual, PROFIBUS, Universal and Universal+ only)
- Control settings (Manual, PROFIBUS, Universal and Universal+ only)
- Help (Manual, PROFIBUS, Universal and Universal+ only)
- Status LEDs (Remote only)
- Troubleshooting
- Error codes
- Error Indication (Remote only)
- Technical support
- Drive maintenance
- Connecting interface tubing
- Ordering information
- Spares and accessories
- Performance data
- Performance curves
- Trademarks
- Publication history
|
8 bit Byte 7 Fail Safe8 bit Byte 8 Fail Safe Speed (Low byte of 16-bit unsigned)8 bit Byte 9 Fail Safe Speed (High byte of 16-bit unsigned)Set Min/Max SpeedsThe Min/Max Speed parameters are used to set the minimum and maximum speed from thePROFIBUS interface. The values are only used if the matching bit in the Control Word isenabled and they are not zero. The values are 16 bit unsigned in 1/10th of RPM of the headspeed.If the user requests the pump to operate at a lower speed than the defined minimum speedfrom the user parameter data (bytes 3, 4) then the pump will operate at the definedminimum speed.If a maximum speed has been configured in the user parameter data, then the pump will belimited to this maximum speed even when the master requests a higher rpm.Fail SafeThe fail-safe user parameter is used to set the correct course of action to take in the eventof a PROFIBUS communications failure. The fail-safe byte is configured as shown in thefollowing table. If no bits are set or an invalid bit pattern is set the default fail safebehaviour shall be to stop the pump.Hex Description0x00 The pump will stop0x01 Continue driving using the last demanded speed0x02 Continue driving using the fail safe speed0x03 - 0x07 ReservedFail Safe SpeedThe fail-safe speed parameter is used to set the speed at which the pump should be drivenif a PROFIBUS communications error occurs and if the fail-safe user parameter is set to0x02.17.5 PROFIBUS data exchangeThe data in this section is provided as reference material for a PROFIBUS network operator.Operating this pump under PROFIBUS control is beyond the scope of this instructionmanual. Consult your PROFIBUS network literature for further information.Default address 126PROFIBUS Ident 0x0E7DGSD File: WAMA0E7D.GSDConfig: 0x62, 0x5D (3 words out, 14 words in)User parameter bytes: 6Cyclic Data Write (from Master to pump)Cyclic Data Write (from Master to pump)16 bit Byte 1 (low), 2 (high) Control Word16 bit Byte 3 (low), 4 (high) Pumphead Speed Setpoint (unsigned)m-qdos-en-02 59