INSTRUCTIONS Line Voltage Track FixtureModels: HTK-793 HTK-794 HTK-795Caution:Read all instructions before installing.Switch off power before installing or re-lamping.Do not attempt to energize anything other than a track light fixture.All installation shall be in accordance with NEC and all local codes.To reduce the risk of a burn during re-lamping, remove from the track before re-lamping.Overview:Fixtures are designed for use on “HT” series WAC Lighting track. They may also be used on othermanufacturer’s brand of track (consult factory for compatibility).Retain instructions for future reference.Lamping:1. HTK-793 use PAR 20 lamp, 50W max.HTK-794 use PAR 30 lamp, 75W max.HTK-795 use PAR 38 lamp, 150Wmax.2. Insert the PAR lamp by screwing clockwiseinto lamp socket.Fixture Installation:1. Note the track head contacts, and the polarity grooverunning the length of the track.2. The two contacts should be positioned so that whenrotated, they will face the grooved side of the track (thisis the side with two flat copper wires running its length).3. Insert adapter into track slot. Pull downward on theadapter while rotating the adapter 90º.4. Release the adapter so the locking tab seats in thetrack slot.5. Removal is the reverse procedure. Track heads maybe positioned anywhere along the track length.6. Not suitable for use on wall mounted track.Retain these instructions for future service and adjustments615 South Street, Garden City, NY 11530Tel: (516) 515-5000 Fax (516) 515-5050www.waclighting.com