6VEEDER-ROOTPGM RSTOP1OP2VEEDER-ROOTPGM RSTOP1OP2VEEDER-ROOTPGM RSTOP1OP2VEEDER-ROOTPGM RSTOP1OP2P R O G R A M M I N GPROGRAM MODEENTERING PROGRAM MODE AND BASIC OPERATIONPARAMETER SEQUENCEPGMPGMPGMfor 3 secondsThe name of the first parameter will appearon the primary display.*Pressing the Scroll Key or no key activity for3 seconds will display the value for thatparameter. The secondary display willindicate the one digit identifier for theparameter. The digit in the secondarydisplay will flash to indicate the unit is inProgram Mode. If the Scroll Key waspressed (instead of waiting 3 seconds), theunit is in Edit Operation, as indicated by theMSD flashing. If there had been no keyactivity for 3 seconds, press the scroll key toenter Edit Operation (MSD flashing). Usethe scroll and edit buttons to change thevalue as in Operation Mode, described onpage 5. Press the Program Key to enter anychanges.Successive presses of the Program Key willscroll the display through the remainingparameters in the Program Mode. To exitProgram Mode, hold the Program Key for 3seconds.The Program Mode can be accessed from theOperation Mode by holding the Program Keyfor 3 seconds.* Parameter names will not appear on themain display if the "Help" function has beendisabled in Program Mode.Funct F23456Funct FCulFor<>Edit OperationFunctionFunction: Determines how the Output 1 will operate in relation to the Set ValueAdjustment Range:Cumulative: Elapsedtime value will continueto accumulate during allinstances when the inputis activeC u l S i nSingle: Time value willdisplay the elapsed timeof an individual input andwill reset to zero for eachsuccessive new pulsePGMDefault Value: Singleno key activityfor 3 secs. orwww.TheTimerAndCounterCompany.com