Vallox 180SE Instructions For Use And Maintenance Manual
Contents |
VALLOX 180 SE12INSTRUCTIONS FOR USING THE CONTROL PANEL© VALLOX • We reserve the right to make changes without prior notification.Basic fan speed = 1Maximum fan speed = 8Carbon dioxide adjustment (CO2 ) = 900 ppm CO2Adjustment interval = 10 min.Freezing protection (cell) = 6 °CFreezing protection hysteresis = 3 °CPreheating setting = 8 °CMaintenance reminder = 4 monthsCell bypass = 12 °CCascade control = not usedHumidity level (RH level) adjustment = automaticSwitch type = fireplace switch3.5. Factory settingsVALLOX 180 SE has the following factory settings3.4. Week clock controlThe week programme can be used to set the desired fan speed (basic fan speed) and supply airtemperature for each hour of the day on seven days a week. The week programme overridesmanual adjustments.Carbon dioxide and humidity adjustment can increase fan speed but never decrease it below thebasic fan speed set in the week programme.3.4.1. Week programme programmingD Hr Sp Tmp1 12 5 20 ExitCursorD Day 1…71 = Monday, 2 = Tuesday, etc.Hr Hours, 0…23Sp Fan speed, 1…8Tmp Supply air temperature, 10...30 ºCExit Save the setting and exitN No change to previousExample: MondayFan speed is increased to speed 2 and supply air temperature to 17 ºC between 07:00 (7 a.m.)and 17:00 (5 p.m.) hours. After that, fan speed is raised to speed 4 and supply air temperature to20 ºC. For the evening, fan speed is boosted to speed 6 between 19:00 and 21:00 hours (for theperiod when a sauna bath is taken), after which fan speed is lowered back to 4.Move the cursor with the arrow keys and change values with the + and – buttons. Note that Exitand saving are done when the programming is finished by moving the cursor below the word Exitand pressing + or –.Changes in fan speed (Sp) and supply air temperature (Tmp) are only made for the hours desired;in other cases, use N (no change to previous).Monday (D = 1), 07:00 hours (H = 7), fan speed 2 (Sp = 2), supply air temperature 17 ºC (Tmp =17). Move the cursor to the following hour.Monday (D = 1), 16:00 hours (H = 16), fan speed 4 (Sp = 4), supply air temperature 20 ºC (Tmp= 20). Move the cursor to the following hour.Monday (D = 1), 19:00 hours (H = 19), fan speed 6 (Sp = 6), supply air temperature unchanged(Tmp = N). Move the cursor to the following hour.Monday (D = 1), 21:00 hours (H = 21), fan speed 4 (Sp = 4), supply air temperature unchanged(Tmp = N). Move the cursor to the following day.Similar changes have to be made separately for each day. Finally, exit the programming mode byselecting Exit. If you wish, you can erase the week programme as indicated in section 3.3.3. Youcan then start programming from the start. You can see the settings programmed by choosing a dayand by scrolling the hours with the + or – button.D Hr Sp Tmp1 7 2 17 ExitD Hr Sp Tmp1 16 4 20 ExitD Hr Sp Tmp1 19 6 N ExitD Hr Sp Tmp1 21 4 N ExitMove the cursor with the arrow keys and change values with the + and – buttons. Exitand saving are done when the programming is finished.Monday (D = 1), hours 15 (H = 15), minutes (M = 30).Time is maintained even though there is a power failure.3.4.2. Adjusting timeday hour min1 15 30 Exitday Day 1…71 = Monday, 2 = Tuesday, etc.hour Hours, 0…23.min Minutes 0…60Exit Save the setting and exitCursor |
Related manuals for Vallox 180SE
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved