Valcom V-9963 Manual
Contents |
3 947008SW2: Priority Port or Line 2 Battery FeedNo battery feed supplied to primary port OFFBattery feed supplied to primary port ONSW3 The 8-position dipswitch provides:SW3-1: DTMF Signaling OptionsNo DTMF signal (single zone) OFFDTMF signal accepted (multi-zone) ONSW3-2, SW3-3: Number of digits to receivebefore recording announcement.1 digit SW3-2 OFF SW3-3 OFF2 digits SW3-2 ON SW3-3 OFF3 digits SW3-2 OFF SW3-3 ON4 digits SW3-2 ON SW3-3 ONSW3-4: Priority Port ModeRecords primary and priority pages,Priority page broadcasts firstOFFPriority page broadcasts in real time.Primary page in progress is recorded andis broadcast after priority page.ONSW3-5: Message Playback ControlPlay message once OFFPlay message twice ONSW3-6, SW3-7: Pre-Page Alert TonesNo Tone SW3-6 OFF SW3-7 OFFSingle Tone SW3-6 ON SW3-7 OFFDual Tone SW3-6 OFF SW3-7 ONQuad Tone SW3-6 ON SW3-7 ONSW3-8: Inter-Page Timing1 second between pages OFF3 seconds between pages ONSW4 The 4-position dip switch provides:SW4-1: Primary or Line 1 Page AccessLoop Detect OFFAudio Detect (VOX) ONSW4-2: Priority or Line 2 Page AccessLoop Detect OFFAudio Detect (VOX) ONSW4-3: Pre “Record” Tone (Enable/Disable)Normal (3 sec. delay of “Ready to Record”tone and “Recording Sequence”)OFFEnableNo tones are issued when “RecordingSequence” is activated. Allows immediate“Record Activation” with a contact closure.ONDisableNOTE: This option is effective only when the inputsare set at Loop Detect (SW 4-1 OFF).SW4-4: Normal or Call Stacker Mode2 Inputs – Primary and Priority OFF2 Inputs will function as Call Stacker ONOther Switches and ControlsSW5: VOX Sensitivity - sets threshold for detectionof audio on the primary and priority ports.SW5 Level SW5 Level0 -20dBm 8 -28dBm1 -21dBm 9 -29dBm2 -22dBm A -30dBm3 -23dBm B -31dBm4 -24dBm C -32dBm5 -25dBm D -33dBm6 -26dBm E -34dBm7 -27dBm F -35dBmLED IndicatorsPLAY: Illuminates when announcement is playing.RECORD: Illuminates during recording of theannouncement.BUSY: Illuminates if, for any reason the unit cannotaccept any more pages.POWER: Illuminates when –24 Vdc and GND isapplied to the unit.TECHNICAL ASSISTANCEWhen trouble is reported, verify the unit is turned onand there are no broken connections leading to theunit.Assistance in troubleshooting is available from thefactory. When calling, you should have a VOM and atelephone test set available and be calling from thejob site. Call (540) 427-3900 and ask for TechnicalSupport, or (540) 427-6000 for Valcom 24-hourAutomated Support or visit our website athttp://www.valcom.com.VALCOM equipment is not field repairable.VALCOM maintains service facilities in Roanoke,VA. Should repairs be necessary, attach a tag to theunit clearly stating your company name, address,phone number, contact person, and the nature of theproblem. Send the unit to:Valcom, Inc.Repair and Return Dept.5614 Hollins RoadRoanoke, VA 24019-5056 |
Related manuals for Valcom V-9963
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved