9Operating Instructions (Continued)7. Close the machine lid to vacuum and sealClose the machine lid, using the lid handle, to begin the vacuum process. Thevacuum cycle will begin at the set vacuum time and count down to zero. Once thevacuum cycle is complete, the seal process will begin. The seal cycle will begin atthe set seal time and count down to zero. Once the seal cycle is complete, air willbe released back into the chamber, and the machine will give a long beep soundindicating that the vacuum and seal cycle is complete.Note: The “SEAL” button is an additional feature that allows you to abort the vacuumprocess and seal the pouch. Press “SEAL” at any time during the vacuum cycle.8. Open the machine lid and inspect the pouchOpen the machine lid using the lid handle. remove the pouch and inspect thevacuum-packaged product.Vacuum confirmation: Check the quality of the vacuum by looking at the tightnessof the pouch and the product. Look for air pockets or air leaks. If you notice that theproduct is not vacuum sealed tightly, then increase the vacuum time by 5 secondsand vacuum and seal again.Seal confirmation: Inspect the pouch seal. A positive seal will appear clear uponinspection. If the seal is spotty or incomplete, increase the seal time by 1 second. Ifthe seal appears white or milky, decrease the seal time by 1 second. Once thesettings are determined for your application, vacuum and seal again.If the product is vacuumed and sealed tightly, then the process is complete.