UniPOS 6130L Instruction Manual
OPTICAL SMOKE DETECTORWITH ADDRESS MODULEOPTI^KO DIMNIJAVLJA^ PO@ARA6130L1. INTRODUCTIONThe Optical Smoke Detector is designed to provideearly warning of a fire condition, by reacting upon afixed smoke concentration level in the protected area.1. UVODOpti~ko dimni detektor je namenjen za otkrivanjepo`ara u ranoj fazi, reaguju}i posle odre|enog pragakoncentracije dima u za{ti}enoj zoni2. STRUKTURA I PRINCIP RADA2. STRUCTURE AND FUNCTIONThe detector consists of two main parts: a base and a detector head. Thelatter comprises a circuit board and a chamber with great sensitiveelement. The contact plates are fixed to the base.The detector head is fixed on the base by the means of bayonet joints.When locating the detector head on the base, make sure the bench markstands about 20 mm before the respective bench mark on the base; thenrotate clockwise to fix. The bench marks should fully coincide when fixed.A flat point screw is provided on the detector head to prevent unauthorizedremoval. A 2 mm tip screwdriver is required for locking and unlocking.The principle of functioning is based upon smoke particles entering thedetector head’s smoke chamber causing distraction of infrared rays withinthe chamber. The activation threshold of the detector is factory set at aspecific smoke concentration level. Upon activation the two red LEDs,situated on the detector head illuminate (3600 visibility). They areextinguished by momentary interruption of the detector’s power supply.Detector’s type and sensitivity are marked.On fig.2 is shown DIP switch for the addresses and the address numberlabel. The DIP switch is protected by a transparent cover. Addressassignment is made through the DIP switch, according Fire Control PanelFS6000 Instruction Manual, Appendix 9. Fire detectors addressing ismade via special communication protocol.3. PREPARING THE DETECTOR FOR OPERATION3.1 Connection diagramConnection diagram of a fire detector base to two-wire fire alarm line,using shielded wire, is shown on fig. 3. Shielded wire is stronglyrecommended for reducing electromagnetic interferences.3.2 MountingSeparate the base from the detector head by tuning the detector head in ananti-clockwise direction.Feed the connection cable through the cable entry in the center of the base.Fix the base on the ceiling using appropriate fixings. Completed the wiringas shown on fig.3. Fix the address label on its appropriate place. Pull theprotection cover and assign the necessary address through the DIP switch.After completion replace the cover and press until a “click” sound isheard.Note: DIP switch should not be set to middle (null) position, because itwould cause an incorrect reception of a fire detector address by the firecontrol panel.Replace the detector head on the base by offering the detector head to thebase ensuring bench marks are no more than 20 mm apart. Rotate thedetector head in a clockwise direction to completed location.Lock the detector head to the base by screwing the flat point screw, usinga 2 mm tip screwdriver, ensure not to over tighten.3.3 TestingTest is made when the fire detector is connected to FS6000 control paneland according the provided test procedures. Place a permanent magnet onthe detector heads surface at the point marked test periphery. The twinLEDs will illuminate. After removing the magnet the LEDs should remainlit until reset by momentary interruption of the power supply. In addition asimulation test of real fire conditions should be completed by a smokeprobe.4. WARRANTYThe manufacturer guarantees compliance with EN 54 Standard, Part 7. Thewarrant period is 36 months from the date of purchase, providing thatrequirements stated in the service schedule have been observed.Detektor se sastoji iz dva osnovna dela: ku}i{ta i glavedetektora. Glava detektora sadr`i {tampanu plo~u i dimnudetektorsku komoru. Kontaktni priklju~ci su fiksirani naku}i{tu.Detekrorska glava je pri~vr{}ena na ku}i{te bajonetnom vezom.Pri postavljanju detektorske glave u ku}i{te reperi na ku}i{tu i glavi trebada su udaljeni oko 20 mm pre upadanja u `leb posle ~ega okrene}emoglavu detektora u smeru kazaljke na ~asovniku. do zabravljivanja. Reperimoraju biti poklopljeni. Pljosnati vijak zabravljiva~ je predvi|en zaspre~avanje neovla{}ene demonta`e. Odvija~ od 2 mm je potreban zazaklju~avanje odn. otklju~avanje.Princip rada je baziran na rasipanju infracrvene svetlosti usled ulaska dimau komoru protivpo`arnog dava~a. To dovodi do aktiviranja fotoprijemnika.Prag aktiviranja je fabri~ki pode{en prema specifi~noj koncentraciji dima.Po aktiviranju oba indikatora na detektorskoj glavi, oni svetle crveno(vidljivo u krugu od 360 0). Resetuju se trenutnim kratkotrajnim prekidomnapajanja detektora.Na detektoru su zna~eni tip i osetljivost detektora.Na slici 2 prikazan je DIP prekida~ za adresiranje i oznaka adrese javlja~a.DIP prekida~ je za{ti}en providnim poklopcem. Postavljanje adrese javlja~avr{i se preko DIP prekida~a, prema Uputstvu adresne centrale FS6000,Poglavlje 9. Adresiranje javlja~a se omogu}ava specijalizovanimprotokolom.3. PRIPREMA JAVLJA^A ZA RAD3.1 Shema vezeShema veze ku}i{ta javlja~a i dvo`ilnog voda sa {irmom je prikazana naslici 3. [irm se obavezno preporu~uje zbog otklanjanja elektromagnetnihinterferenci.3.2 Monta`aRazdvojiti ku}i{te od glave detektora okre}u}i ga suprotono kretanjukazaljke na satu.Provu}i kabli kroz centralni otvor na ku}i{tu. Pri~vrstiti ku}i{te za zid iliplafon odgovaraju}om vij~anom vezom. Izvr{iti o`i~enje kao {to jeprikazano na slici 3. Postaviti oznaku adrese na odgovaraju}e mesto.Ukloniti za{titni poklopac i dodeliti adresu pomo}u DIP prekida~a. Vratitiza{titni poklopac pritiskaju}i ga dok se ne ~uje zvuk “klik”.Napomena: DIP prekida~ ne setovati u srednji (nulti) polo`aj zato {to }eusloviti neta~nu detekciju po`ara protivpo`arne centrale.Vratiti glavu detektora u ku}i{te tako da reperi budu udaljeni oko 20 mm.Okrenimo glavu detektora u smeru kazaljke na satu do zabravljenja.Osigurajmo glavu detektora za ku}i{te pomo}u zabravljiva~a, ne prete`u}i,pomo}u dvomilimetarskog odvija~a.3.3 TestTest se sprovodi kada je javlja~ vezan za protivpo`arnu centralu premapredvi|enoj test proceduri. Staviti permanentni magnet na povr{inu glavedetektora na mestu TEST. Indikatori treba da svetle. Posle pomeranjamagneta indikatori moraju i dalje da svetle sve do resetovanja indikatora.Test se mo`i izvr{iti i dimnom probom.4. GARANCIJAProizvo|a~ garantuje da proizvod odgovara EN 54, Part 7. Garancijski rokje 36 meseci od dana kupovine, samo pod uslovima navedenim u servisnomplanu. |
Related manuals for UniPOS 6130L
UniPOS RI31 Instruction Manual
UniPOS RI31 Instruction Manual
UniPOS FD7130M Instruction Manual
UniPOS FD 7130 Instruction Manual
UniPOS FD 7130 Instruction Manual
UniPOS FD8040 Instruction Manual
UniPOS FD8030 Instruction Manual
UniPOS YKB-02? Instruction Manual
UniPOS FD 8030 Instruction Manual
UniPOS FD 3030 Instruction Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved