13 www.ubisys.de Empty string by default. Might be set by commissioning software during installation0x0011 unsigned8,persistentPhysicalEnvironment“Unspecified” by default. Might be set by commissioning software during installationCluster commands supported:Command Description0x0000 Reset to factory defaults.Restores the values of all attributes of all clusters across all endpoints to their factory fresh defaultsettings. Does not affect network settings or bindings.Notice: In the current version, the command does actually behave like a leave command with factory reset.This will be fixed in a future release.7.2.2. Identify Cluster (Server)Attributes supported:Attribute Type Description0x0000 unsigned16 IdentifyTimeThe remaining time, in seconds, the device will be identifying itself.Notice that R0 currently does not provide any visual feedback in identify mode.Cluster commands supported:Command Description0x0000 IdentifyPuts the device into identify mode, or terminates identify mode.0x0001 Query IdentifyDetermines whether the device is currently identifying, and returns the remaining time if so.7.2.3. Commissioning Cluster (Server)This implementation supports all attributes and most commands. However, the cluster has limitedvalue. It is rarely used and might be removed in the future.7.2.4. Over-the-Air Upgrade Cluster (Client)The image type for R0 is 0x7b0a. You may request the latest firmware in ZigBee OTA image format toupgrade devices in the field using your own OTA server and back-end. If you operate the Router R0together with the ZigBee/Ethernet Gateway ubisys G1, the latest firmware for R0 will always beavailable automatically and you do not need to request it explicitly.