Ubisys S1-R Quick Start Manual
Also see for Power Switch S1-R: Quick start guideReference manualIntegrator guideManual
As per 01/2018Page 1/2SpecificationsThe power switch S1-R is a radio controlled universal switch actuator withintegrated power consumption measurement. In the current flush mountversion, it is compatible to standard switch boxes and fully integrates into therest of your smart home. It is not only suitable for new buildings, but also forexisting buildings, because retrofitting has, due to use of radio technology,no special requirements to the electrical installation. For new buildings andrenovations, it helps reducing both planning and cabling costs. The systemcan gradually be extended by adding new components. Determine scope andtiming at any time by yourself.The power switch S1-R offers full functionality when combined with othercomponents of the ubisys smart home product line and allows for example:• Freely configurable assignments between control elements and consu-mers• Scenes and group controlling• Time and event controlled actions• Continuous metering• Surveillance• Controlling via smart home display, smartphone app or, as usual, viabutton or switchMore information about the features of the ubisys smart home product linecan be found at www.ubisys.de.InstallationThe power switch S1-R meets the requirements of DIN 43880 and isdesigned for installation in fuseboxes, mounted on cap rails according toEN50022.Leads: Dimensions:The power switch S1-R retains its switch position when disconnected frompower. The switch position is undefined by delivery; i. e. the switching outputcan be conductively connected to the phase L!During installation, the general risks of household voltage networks have tobe noted!Basic ZigBee CommissioningThe device joins an open ZigBee network when it is factory new and poweris applied.Funkvernetzt mitStromverbrauchs-messungUniversal-dimmer D1-R230 V~/50 Hz500 VAFunkvernetzt mitStromverbrauchs-messungJalousie-steuerung J1-R230 V~/50 Hz500 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S1-R230 V~/50 Hz3.680 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S2-R230 V~/50 Hz2 x 500 VAFunkvernetzt mitStromverbrauchs-messungUniversal-dimmer D1-R230 V~/50 Hz500 VAFunkvernetzt mitStromverbrauchs-messungJalousie-steuerung J1-R230 V~/50 Hz500 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S1-R230 V~/50 Hz3.680 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S2-R230 V~/50 Hz2 x 500 VA90 mm18 mm(1 TE)60,5 mm90 mm18 mm(1 TE)60,5 mm90 mm18 mm(1 TE)60,5 mm90 mm18 mm(1 TE)60,5 mmFactory ResetPower-Cycle Sequencing Factory Reset: It is possible to instigate a factoryreset using a special power-cycle sequence. This is equivalent to selectingmenu item #5, with the advantage that you need no access to the deviceitself (only to its power supply).1. Power the device for at least four seconds.2. Interrupt the power supply for at least a second.3. Reapply power for less than two seconds but more than half a second.Notice that at the end of this cycle, the device is off and should remain off forat least a second.4. Repeat the previous step two more times, for a total of three shortpower cycles.5. Apply power to the device and leave it powered on. The device will nowfactory reset and reboot.Factory Reset via Button: To reset the device to its factory fresh settings(e.g. in order to join it to another network afterwards), press the button in thelarger of the two holes on the front for more than 10 seconds until the LEDstarts flashing rapidly.*)Only use the electrically isolated tool provided with the device to press thebutton in the hole.*) If the device has legacy firmware this feature might not be available. In thiscase, keep the button pressed for one second, until the LED flashes threetimes and then blinks once every second. Then press the button four timesfor less than a second, until the LED flashes five times, followed by a pause,then flashes five times again, followed by a pause, etc. In this state, keep thebutton pressed for more than a second until the LED starts flashing rapidly.ConfigurationUpon delivery the factory settings of power switch S1-R has switching inputassigned to the corresponding switching output. So it can initially be opera-ted autonomously without a radio network. Input port 2 is not configured bydefault.For integration into the smart home radio network, the power switch S1-Rhas to be configured first. Direct access to the power switch S1-R is notnecessary for configuration. That means that network configuration can alsobe done after successful electrical installation. It is best to hold the 16 digitserial number of the power switch S1-R in the construction plan duringinstallation. This allows you to allocate the device at a later point.When connected to power, the power switch S1-R automatically logs into theZigBee network. After that it can be configured via the electrician’s installati-on software (ubisys Network Manager) or the ubisys smartphone app.More information about adding and configuring ubisys smart home compon-ents can be found in the ubisys Smart Home Installation manual.Technical InformationRated voltage 230 V ~, 50 HzMax. switching power 3,680 VAOwn consumption 0.3 WRadio technology ZigBee 3.0 in 2.4 GHz ISM Band,IEEE 802.15.4 channels 11-26, 0…5dBmtransmitting power *)Environment temperature -20°C - +45°C*) More information about radio technology can be found at www.ubisys.de.FunkStrommessUnivdimm230500Funkvernetzt mitStromverbrauchs-messungJalousie-steuerung J1-R230 V~/50 Hz500 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S1-R230 V~/50 Hz3.680 VAFunkvernetzt mitStromverbrauchs-messungLeistungs-schalter S2-RButtonLEDButtonLEDButtonLED230 V~/50 Hz2 x 500 VAPower switch S1-RRadio linked with power consumption measurement |
Related manuals for Ubisys Power Switch S1-R
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved