Ubisys C4 Quick Start Manual
Also see for C4: Integrator guideQuick start guide
As per 02/2017Page 1/2SpecificationsThe control unit C4 is a radio controlled device with 4 universal inputs tocontrol further smart home components. In the current flush mount version,it is compatible to standard switch boxes and fully integrates into the rest ofyour smart home. It is not only suitable for new buildings, but also for existingbuildings, because retrofitting has, due to use of radio technology, no specialrequirements to the electrical installation. For new buildings and renovations,it helps reducing both planning and cabling costs. The system can graduallybe extended by adding new components. Determine scope and timing at anytime by yourself.The control unit C4 is an additional option and offers full functionality whencombined with other components of the ubisys smart home product line andallows for example:• Freely configurable assignments between control elements and consu-mers• Scenes and group controlling• Can be connected to switches and motion sensorsMore information about the features of the ubisys smart home product linecan be found at www.ubisys.de.InstallationThe control unit C4 is designed for installation in flush mounted socketsaccording to DIN 49073. For installation behind a switch, power socket ormotion sensor, deep sockets are recommended.Leads: Dimensions:For installation of the control unit C4, the included clamps can be used.During installation, the general risks of household voltage networks have tobe noted!Basic ZigBee CommissioningThe device joins an open ZigBee network when it is factory new and poweris applied.Funkvernetzt mitStromverbrauchsmessungLeistungsschalter S2230 V ~ / 50 Hz, 2 x 500 VA2 12 1ngsschalter S1netzt mitrbrauchsmessung/ 50 Hz, 3.680 VAFunkvernetztBedieneinheit C4AC 230 V ~ / 50 Hz2 14 3etztr R0V ~ / 50 HzFunkvernetzt mitStromverbrauchsmessungUniversaldimmer D1230 V ~ / 50 Hz, 500 VA2 1 2 14 3FunkvernetztBedieneinheit C4AC 230 V ~ / 50 Hz2kvernetztuter R0V ~ / 50 Hz2Router R0290 - 270 V~, 50/60 Hz(12 - 400 V=)43 mm43 mm12 mm143 mm12 mm 47 mm 12 mm 47 mm43 mm12 mm143 mm12 mm47 mm43 mm12 mm12 mm 47 mm43 mm12 mm143 mm12 mmFactory ResetPower-Cycle Sequencing Factory Reset: It is possible to instigate a factoryreset using a special power-cycle sequence. This is equivalent to selectingmenu item #5, with the advantage that you need no access to the deviceitself (only to its power supply).1. Power the device for at least four seconds.2. Interrupt the power supply for at least a second.3. Reapply power for less than two seconds but more than half a second.Notice that at the end of this cycle, the device is off and should remain off forat least a second.4. Repeat the previous step two more times, for a total of three shortpower cycles.5. Apply power to the device and leave it powered on. The device will nowfactory reset and reboot.Factory Reset via Button: To reset the device to its factory fresh settings(e.g. in order to join it to another network afterwards), press the button in thelarger of the two holes on the front for more than 10 seconds until the LEDstarts flashing rapidly.*)Only use the electrically isolated tool provided with the device to press thebutton in the hole.*) If the device has legacy firmware this feature might not be available. In thiscase, keep the button pressed for one second, until the LED flashes threetimes and then blinks once every second. Then press the button four timesfor less than a second, until the LED flashes five times, followed by a pause,then flashes five times again, followed by a pause, etc. In this state, keep thebutton pressed for more than a second until the LED starts flashing rapidly.ConfigurationThe control unit C4 has 4 inputs. Every single input can be configured indivi-dually and can be used to control smart home components.For integration into the smart home radio network, the control unit C4 has tobe configured first. Direct access to the control unit C4 is not necessary forconfiguration. That means that network configuration can also be done aftersuccessful electrical installation. It is best to hold the 16 digit serial numberof the control unit C4 in the construction plan during installation. This allowsyou to allocate the device at a later point.When connected to power, the control unit C4 automatically logs into theZigBee network. After that it can be configured via the electrician’s installati-on software (ubisys Network Manager) or the ubisys smartphone app.More information about adding and configuring ubisys smart home compon-ents can be found in the ubisys Smart Home Installation manual.Technical InformationRated voltage 230 V ~, 50 HzOwn consumption 0.3 WRadio technology ZigBee 3.0 in 2.4 GHz ISM Band,IEEE 802.15.4 channels 11-26, 0…5dBmtransmitting power *)Environment temperature -20°C - +45°C*) More information about radio technology can be found at www.ubisys.de.Funkvernetzt mitStromverbrauchsmessungLeistungsschalter S2230 V ~ / 50 Hz, 2 x 500 VA2 12 1Leistungsschalter S1Funkvernetzt mitStromverbrauchsmessung230 V ~ / 50 Hz, 3.680 VAFunkvernetzt mitStromverbrauchsmessungJalousiesteuerung J1230 V ~ / 50 Hz, 500 VA2 1 2 1Funkvernetzt mitStromverbrauchsmessungUniversaldimmer D1230 V ~ / 50 Hz, 500 VA2 1FunkvernetztBedieneinheit C4AC 230 V ~ / 50 Hz2 14 3FunkvernetztRouter R0AC 230 V ~ / 50 HzButtonLEDButtonLEDButtonLEDButtonLEDButtonLEDButtonLEDRouter R0ButtonLED90 - 270 V~, 50/60 Hz(12 - 400 V=)Control unit C4Radio linked |
Related manuals for Ubisys C4
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved