URC VL-9534-MD-X Installation Instructions Manual
INSTALLATION INSTRUCTIONSWARNING:• Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring.• Never wire any electrical device with power turned on. Wiring dimmer with power onmay cause permanent damage to dimmer and void warranty.• If you are not sure about any part of these instructions, please contact alicensed electrician.CAUTION:1. Use only with 120V AC 60 Hz.2. Do not exceed maximum rating of the dimmer as indicated on the device.3. Must be installed and used in accordance with electrical codes.4. If a bare copper or green ground connection is not available in the wallbox, contact alicensed electrician for installation.5. For use ONLY with permanently installed 120V AC incandescent/halogen fixtures.6. To avoid overheating and possible damage to other equipment, do not use to controlreceptacles, fluorescent lights, motor-driven appliances, transformer suppliedappliances, etc.7. Use only #14 or #12 copper wire rated for at least 75º C with these devices.8. Minimum Lamp Wattage:Single Location Control = 60 Watts.Multi-location Control = 100 WattsNOTES:1. The RF Master Dimmer (VL-9534-MD-X) is wired directly to the light fixture.2. For multi-location installations one RF Master Dimmer is used with RF AccessoryDimmer(s) VL-9542-AD-X.3. The VL-9542-AD-X requires hardware connection to the RF Master Dimmer. Refer toinstallation instructions for wiring.4. The RF Master Dimmer is not compatible with standard 3-way switches.5. For multi-location installations, the RF Master Dimmer is the only device that isincluded in the RF Network.6. Do not exceed maximum load of 600 watts.Z-Wave Device Network Installation Instructions for RF Master Dimmer Only:1. This product may be added to a new or existing Z-Wave network. The device has ablue LED, which will blink when the device is not included in a Z-Wave network. TheLED stops blinking when the RF Master Dimmer is in a network.2. To include this device in a Z-Wave network, select the command on your Z-Wavecontroller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Thenpress the RF Master Dimmer ON/OFF switch one time to include it in the network.The LED will stop blinking.3. To exclude this device from a Z-Wave network, select the command on yourZ-Wave controller for exclusion (Uninstall, Remove Device, Remove Node,Exclude Device, etc.). Then press the RF Master ON/OFF switch one time to excludeit from the network. The LED will start blinking.4. This product works with other Z-Wave products from different vendors andproduct categories as part of the same network.5. This product is a listening node and it will act as a repeater in the Z-Wavenetwork. It will perform the repeater function with Z-Wave products.6. For multi-location install; blue LED will blink on all wired units, when the RF MasterDimmer (VL-9534-MD-X) is not included in the Z-Wave network. After including theRF Master Dimmer in the Z-Wave network, the LED will stop blinking. TheVL-9542-AD-X (no neutral) Accessory Dimmer need not be included in the Z-Wavenetwork.IMPORTANT:RF Master Dimmer will not work or will become damaged if wired incorrectly and thewarranty will be voided.Troubleshooting GuideSymptom Possible Cause SolutionNo Function. LEDs is OFF A) Light bulb(s) burned outB) Circuit breaker is off ortrippedC) Disconnect switch on thedimmer is pulled out to theOFF positionD) Improper wiringE) Defective dimmerA) Replace light bulbB) Turn on the circuit breakerC) Push in the disconnectswitch on the dimmerD) Check and correct wiringE) Replace dimmerErratic operation or flickeringLEDsA) Lamp power is less than60 WattsB) Loose wiring connectionsA) Increase lamp power to atleast 60 WattsB) Check and correct wiringFunctions normally using thedimmer push buttons but notfrom Z-Wave controller andone of the blue LEDs blinksON and OFF about once persecondDimmer is not included inZ-Wave networkInclude dimmer in a Z-Wavenetwork using a Z-Wavecontroller. Refer to Z-Wavecontroller user manual fordetailsFunctions normally using theMaster dimmer control butnot from Z-Wave controllerand no LEDs are blinkingProblem with RFcommunication on dimmerA) Relocate Z-Wave controllerB) Replace dimmerFunctions normally both lo-cally and from a Z-Wave con-troller but can’t be controlledfrom a dimmer accessoryswitch (VL-9542-AND-X) orother Z-Wave deviceThe dimmer accessory orother Z-Wave device is notassociated with the dimmeryou wish to controlCreate an associationbetween the dimmer acces-sory or other device and thedimmer. Refer to your Z-Wavecontroller user manual fordetailsDimmer is warm to touchafter a period of timeThis is normal No action required(Cut if necessary)Strip 5/8”Suggested ToolsON/OFF SWITCH• Press once to turn lights ON at previously selected level.• Press again to turn lights OFF.• When lights are OFF, press and hold for 2 seconds for full brightness.• When lights are ON, press and hold for 2 seconds until the blue LED blinks. After thepreset delay, the lights will begin fading to OFF (up to 4 minutes).• ON/OFF LED indicates that dimmer is turned on.READ BEFORE INSTALLATION!Switch IdentificationACCESSORYACCESSORYACCESSORYMaster Control(VL-9534-MD-X)Accessory(VL-9542-AD-X)Disconnect SwitchRedBlackGreenGreenBlueBlueRF MASTER DIMMER – VL-9534-MD-X FOR INCANDESCENT FIXTURES ONLY / NO NEUTRAL REQUIREDRF ACCESSORY DIMMER – VL-9542-AD-X |
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved