UE Systems Ultraprobe 3000 Instructions Manual
Also see for Ultraprobe 3000: Instruction manualManual
10/31/11Conducting a Compressed Air Leak Survey Using the Ultraprobe 3000 (Self-Survey)Request the Ultraprobe 3000.1. Request the use of the Ultraprobe 3000 ultrasonic leak detector from your electric utility.(There is no fee to borrow the Ultraprobe.)2. You may borrow the Ultraprobe for one week. Additional time may be available upon request.Prepare for the leak survey.1. Items you will need to conduct an air leak survey:a. Ultraprobe 3000 and holsterb. clipboard and Compressed Air Leak Tracking Form to record leak locationsc. tags to affix to air leak locationsd. tools to repair simple leaks during the surveye. digital camera (optional)2. Agree to the Ultraprobe Terms of Use.3. Review these instructions.4. The Ultraprobe should be charged for one hour before use using the charger included in thecase. A fully charged battery will provide about 2 hours of use. A green light on the chargerindicates the battery is fully charged.Using the Ultraprobe.1. Attach the rubber focusing probe to the end (silver module) of the Ultraprobe.2. Plug the headphones into the “Phones” jack on the Ultraprobe. The Ultraprobe headphonesallow you to “hear” the turbulence caused by an air leak.3. Press and hold the trigger of the Ultraprobe while using it to scan your compressed air system.4. Leaks will be heard as a “rushing/whooshing” sound through the headphones. As you scan forleaks by sweeping the Ultraprobe over your compressed air system, start by adjusting thesensitivity volume to the maximum (S=70) by turning the Sensitivity knob clockwise. Reduce thesensitivity by turning the knob counter-clockwise if the ultrasound level is too high to identifythe direction of the leak. Continue to adjust the sensitivity as you hone-in on the air leak.Follow the sound to the loudest point to identify a leak.Search for compressed air leaks.1. Clear the Ultraprobe memory:a. Make sure the Ultraprobe is off.b. Press and hold the Sensitivity knob on the Ultraprobe while you squeeze the trigger untilthe MENU is displayed.c. Continue to squeeze the trigger during the remaining steps but release the Sensitivityknob.d. Turn the Sensitivity knob clockwise one click until “MENU 02 – Delete Records” isdisplayed.e. Push the Sensitivity knob in to select “Delete Records”f. Turn the Sensitivity knob clockwise one click until “YES” is displayed.g. Push the Sensitivity knob in to confirm “Delete Records”h. After all 400 records have been cleared from memory, release the trigger.2. Starting from your air compressor, use the Ultraprobe to scan your compressed air systempiping, hoses, regulators and end-uses. |
Related manuals for UE Systems Ultraprobe 3000
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved