E65819224[Setup values of f742 to f745]DefaultsettingCommunicationNo.Trace (monitor) functionCommunication unit attracing0 FD00 Output frequency (Hz/free unit) 0.01Hz1 FD03 Output current (%/A) 0.01%2 FD02 Frequency command value (Hz/ freeunit) 0.01Hz3 FD04 Input voltage (DC detection) (%/V) 0.01%4 FD05 Output voltage (command value) (%/V) 0.01%5 FD29 Input power (kW) 0.01kW6 FD30 Output power (kW) 0.01kW7 FD18 Torque (%) 0.01%9 FD23 Motor cumulative load factor (%) 0.01%10 FD24 Inverter cumulative load factor (%) 0.01%11 FD25 PBR (Braking resistor) cumulative loadfactor (%) 0.01%12 FD15 Motor primary frequency (Hz/ free unit) 0.01Hz13 FE35 VIA input value (%) 0.01%14 FE36 VIB input value (%) 0.01%18 FA51 Arbitrary code from communication -20 FE37 VIC input value (%) 0.01%21 FE56 Pulse train input value (pps) 1pps23 FD22 PID feedback value (Hz/ free unit) 0.01Hz24 FE76 Input power According tof74925 FE77 Output power26 FE26 Motor load factor (%) 1%27 FE27 Drive load factor (%) 1%40 FD06 Input terminal status -41 FD07 Output terminal status -42 FD01 Inverter status -Ex.) When using the S3 terminal as the tracing back trigger signal terminalTitle Function AdjustmentrangeExample of settingf116 Input terminal functionselection 6 (S3) 0-203 76: Trace back trigger signalSetting value 77 is reverse signal.Note 1: If the inverter trips when no trigger signal is given, trace data is overwritten withtripping data.Note 2: Trace data is overwritten each time a trigger signal is given.Note 3: When retry operation is occurred, the data at first tripping is written. The trace data iscleared at retry success.