Toshiba RAV-SM564UTP-E Installation Manual
Also see for RAV-SM1104UTP-E (TR): Service manualService manualInstallation manualService manual
– 34 –4 InstallationREQUIREMENTStrictly comply with the following rules to prevent damage of the indoor units and human injury.• Do not put a heavy article on the indoor unit. (Even units are packaged)• Carry in the indoor unit as it is packaged if possible. If carrying in the indoor unit unpacked by necessity, be sure touse buffering cloth, etc. to not damage the unit.• To move the indoor unit, hold the hooking metals (4 positions) only.Do not apply force to the other parts (refrigerant pipe, drain pan, foamed parts, or resin parts, etc.).• Carry the package by two or more persons, and do not bundle it with plastic band at positions other than specified. External view (Unit: mm)(mm)Model RAV- A B C D Model RAV- A B C DSM56 Type 256 Ø6.4 Ø12.7 120 SM140 Type 319 Ø9.5 Ø15.9 183SM80 Type 256 Ø9.5 Ø15.9 120 SM160 Type 319 Ø9.5 Ø15.9 183SM110 Type 319 Ø9.5 Ø15.9 183Ceiling bottomsurface Knockout square holefor divide ductFor Ø150Knockout squarehole for divide ductFor Ø150840 Unit external dimensionCeiling bottom surfaceElectricalcontrol boxRefrigerant pipeconnecting port(Liquid) BRefrigerant pipeconnecting port(Gas) CTake-in portof wiresCeilingbottomsurfaceDrain pipeconnectingportKnockout square holefor divide ductFor Ø150Hanging bolt M10 or Ø3/8(Locally procured)Knockout square hole for divide ductFor Ø150690 ± 20 Hanging bolt pitch860 to 910 Ceiling opening dimension950 Panel external dimensionKnockout square hole for humidifierCeiling panel (sold separately)Ceiling bottom surfaceZ viewKnockout forsimple OAFor Ø100Ceiling bottomsurface860 to 910 Ceiling opening dimension780 Hanging bolt pitch950 Panel external dimension Opening a ceiling andinstallation of hanging bolts• Consider the piping / wiring before the unit is hungwhen determining the location of the indoor unitinstallation and orientation.• After the location of the indoor unit installation hasbeen determined, open the ceiling and installhanging bolts.• The dimensions of the ceiling opening and hangingbolt pitches are given in the outline drawing and theattached installation pattern.• When a ceiling already exists, lay the drain pipe,refrigerant pipe, indoor unit / outdoor unit connectionwires, and remote controller wires to their connectionlocations before hanging the indoor unit.Procure hanging bolts and nuts for installing the indoorunit (these are not supplied).◆ How to use the installation pattern(accessory)The installation pattern is provided inside thepackaging cap. |
Related manuals for Toshiba RAV-SM1104UTP-E (TR)
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved