Toshiba RAS SKV Series Installation Manual
44 mmPiping and Drain Hose Installation* Since dewing results in a machine trouble, make sure to insulate bothconnecting pipes. (Use polyethylene foam as insulating material.)Piping and drain hose forming1. Die-cutting front panel slitCut out the slit on the leftward or right side of the front panel for the leftor right connection and the slit on the bottom left or right side of the frontpanel for the bottom left or right connection with a pair of nippers.How to remove the drain capClip the drain cap by needle-nosepliers and pull out.How to remove the drain hose• The drain hose can be removed by removing thescrew securing the drain hose and then pulling outthe drain hose.• When removing the drain hose, be careful of anysharp edges of steel plate. The edges can injuries.• To install the drain hose, insert the drain hosefirmly until the connection part contacts with heatinsulator, and then secure it with original screw.How to fix the drain cap1) Insert hexagon wrench (4 mm)in a center head.2) Firmly insert the drain cap.Firmly insert the drain hose and drain cap; otherwise, water may leak.In case of right or left piping• After scribing slits of the front panel with aknife or a making-off pin, cut them with apair of nippers or an equivalent tool.In case of bottom right or bottom left piping• After scribing slits of the front panel with aknife or a making-off pin, cut them with apair of nippers or an equivalent tool.Left-hand connection with piping• Bend the connecting pipe so that it is laid within 43 mm above the wallsurface. If the connecting pipe is laid exceeding 43 mm above the wallsurface, the indoor unit may unstably be set on the wall.When bending the connecting pipe, make sure to use a spring bender soas not to crush the pipe.Bend the connecting pipe within a radius of 30 mm.To connect the pipe after installation of the unit (figure)How to install the air inlet grille on the indoorunit• When attaching the air inlet grille,the contrary of the removedoperation is performed.Wiring ConnectionWiring of the connecting cable can be carried out without removing thefront panel.1. Remove the air inlet grille.Open the air inlet grille upward and pull it toward you.2. Remove the terminal cover and cord clamp.3. Insert the connecting cable (according to the local cords) into the pipe holeon the wall.4. Take out the connecting cable through the cable slot on the rear panel sothat it protrudes about 15 cm from the front.5. Insert the connecting cable fully into the terminal block and secure it tightlywith screws.6. Tightening torque : 1.2 N·m (0.12 kgf·m)7. Secure the connecting cable with the cord clamp.8. Fix the terminal cover, rear plate bushing and air inlet grille on the indoorunit.How to connect the connecting cable• Be sure to refer to the wiring system diagram labeled inside the frontpanel.• Check local electrical cords and also any specific wiring instructions orlimitations.NOTE• Use stranded wire only.• Wire type : More than H07RN-F or 60245 IEC66 (1.0 mm2 or more)CAUTIONCAUTIONCord clampTerminal blockTerminal coverScrewEarth lineScrew Connecting cableScrewRear rightRear leftBottom leftLeftBottom rightRightDie-cuttingfront panel slitChangingdrain hosePiping preparationHeat insulatorDrain hoseDo not apply lubricating oil(refrigerant machine oil) wheninserting the drain cap. Applicationcauses deterioration and drainleakage of the plug.Insert a hexagonwrench (4 mm).No gap!!270 mm230 mm43 mmLiquid sideGas side(To the forefront of flare)Outward form of indoor unitR 30 mm (Use polisin (polyethylene)core or the like for bending pipe.)Use the handle of screwdriver, etc.SlitSlitNOTEIf the pipe is bent incorrectly, the indoor unit may unstably be set on the wall.After passing the connecting pipe through the pipe hole, connect theconnecting pipes to the auxiliary pipes and wrap the facing tape aroundthem.ConnectingcableEarth lineStripping length of the connecting cable110 mm50 mm10 mm10 mm2. Changing drain hoseFor leftward connection, bottom-leftward connection and rearleftwardconnection’s piping, it is necessary to change the drain hose and draincap. *. '' |