Toshiba RAS-10N3KV2 Series Owner's Manual
Also see for RAS-10N3AV2 Series: Owner's manualOwner's manualOwner's manualInstallation manualInstallation manual
Set your preferred operation for future use. The setting will be memorized by theunit for future operation (except airflow direction).1. Select your preferred operation.2. Press and hold for 3 seconds to memorize the setting.The P mark displays.3. Press : Operate the preset operation.To automatically restart the air conditioner after the power failure (Power of theunit must be on.)Setting1. Press and hold the RESET button on the indoor unit for 3 seconds to setthe operation. (3 beep sound and OPERATION lamp blink 5 time/sec for5 seconds)2. Press and hold the RESET button on the indoor unit for 3 seconds to cancelthe operation. (3 beep sound but OPERATION lamp does not blink)• In case of ON timer or OFF timer are set, AUTO RESTART OPERATIONdoes not activate.To operate at super low fan speed for quiet operation (except in DRY mode)Press QUIET : Start and stop the operation.Note: Under certain conditions, QUIET operation may not provide adequatecooling due to low sound features.For comfortable sleep, automatically control air fl ow and automatically turn OFF.Press : Select 1, 3, 5 or 9 hrs for OFF timer operation.Note: The cooling operation, the set temperature will increase automatically1 degree/hour for 2 hours (maximum 2 degrees increase). For heatingoperation, the set temperature will decrease.Firstly, turn off the circuit breaker.Filter Reset (Some models only)FILTER lamp lights on; the fi lter must be cleaned.To turn off the lamp, push the RESET button on the indoor unit or the FILTERbutton on the remote control.Indoor Unit and Remote Control• Clean the indoor unit and the remote control with a wet cloth when needed.• No benzine, thinner, polishing powder or chemically-treated duster.1. Three-minute protection feature: To prevent the unit from being activatedfor 3 minutes when suddenly restarted or switched to ON.2. Preheating operation: Warm up the unit for 5 minutes before blowing warm air.3. Warm air control: When the room temperature reaches the set temperature,the fan speed is automatically reduced and the outdoor unit will stop.4. Automatic defrosting: Fans will stop during defrost operation.5. Heating capacity: Heat is absorbed from outdoor and released into the room.When the outdoor temperature is too low, use another recommended heatingapparatus in combination with the air conditioner.6. Consideration for accumulated snow: Select the position for outdoor unit whereit will not be subjected to snow drifts, accumulation of leaves or other seasonaldebris.7. Some minor cracking sound may occur when unit operating. This is normalbecause the cracking sound may be caused by expansion/contraction ofplastic.Note: Item 2 to 6 for Heating modelAir conditioner operating conditionsTo protect bad smell caused by the humidity in the indoor unit.1. If the button is pressed once during “Cool” or “Dry” mode,the fan will continue to run for other 30 minutes, then it will turn offautomatically. This will reduce the moisture in the indoor unit.2. To stop the unit immediately, press the more 2 times within30 seconds.Temp.OperationOutdoor Temperature RoomTemperatureHeating –15°C ~ 24°C Less than 28°CCooling –10°C ~ 46°C 21°C ~ 32°CDry –10°C ~ 46°C 17°C ~ 32°CTo separate using of remote control for each indoor unit in case of 2 airconditioners are installed nearly.Remote Control B Setup.1. Press RESET button on the indoor unit to turn the air conditioner ON.2. Point the remote control at the indoor unit.3. Push and hold button on the Remote Control by the tip of the pencil.“00” will be shown on the display.4. Press during pushing . “B” will show on the display and “00”will disappear and the air conditioner will turn OFF. The Remote Control Bis memorized.Note: 1. Repeat above step to reset Remote Control to be A.2. Remote Control A has not “A” display.3. Default setting of Remote Control fromfactory is A.The unit does not operate. Cooling or Heating is abnormally low.• The power main switch is turnedoff.• The circuit breaker is activated tocut off the power supply.• Stoppage of electric current.• ON timer is set.• The fi lters are blocked with dust.• The temperature has been setimproperly.• The windows or doors are opened.• The air inlet or outlet of the outdoorunit is blocked.• The fan speed is too low.• The operation mode is FAN or DRY.OPERATION AND PERFORMANCE19TROUBLESHOOTING (CHECK POINT)20REMOTE CONTROL A-B SELECTION21PRESET OPERATION13AUTO RESTART OPERATION14QUIET OPERATION15COMFORT SLEEP OPERATION16MAINTENANCE17SELF CLEANING OPERATION (COOL ANDDRY OPERATION ONLY)1821TSB 1110650197_(01_EN).indd 5TSB 1110650197_(01_EN).indd 5 11/22/12 4:09 PM11/22/12 4:09 PM |
Related manuals for Toshiba RAS-10N3AV2 Series
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved