Document Number: 60172 1ASD-MTG-KIT9 Installation ProcedureThe ASD may be controlled from a remotely-mounted Electronic Operator Interface (EOI).The EOI can operate up to distances of up to 15 feet away from the ASD via the RS485 Port.An EOI extender cable is required for remote mounting. Extender cables are available in lengths of 7, 10,or 15 feet and may be ordered through your sales representative.Required Remote-mount HardwareEOI Remote-Mount Assembly• ASD-MTG-KIT9 Assy.Extender Cables• Cable, RJ45, 7 ft. — P/N ASD-CAB7F• Cable, RJ45, 10 ft. — P/N ASD-CAB10F• Cable, RJ45, 15 ft. — P/N ASD-CAB15FMounting PrecautionsMount the unit securely in a well ventilated area that is out of direct sunlight using the four mountingstuds of the ASD-MTG-KIT9 Assy. The ambient operating temperature of the EOI is 14 – 104° F(-10 – 40° C).Read and adhere to the Safety Precautions and Warnings of the Installation andOperation Manual of the ASD.When mounting the ASD-MTG-KIT9:• Select a mounting location that is easily accessible by the user.• Avoid installation in areas where vibration, heat, humidity, dust, metal particles, or high levels ofelectrical noise (EMI) are present.• Do not install the EOI where it may be exposed to flammable chemicals or gasses, water, solvents, orother fluids.• Turn the power on only after securing the front cover or securing the door of the ASD.Plate Installation and Module Removal/InstallationReference Figures 1 and 2 on pg. 2 for instructions 5 – 8 below.1. At the Remote EOI mounting location, identify and mark the locations of the 4.56” by 4.44” holeand the four 7/32” screw holes (see Figure 1).2. Cut the 4.56” by 4.44” rectangular mounting hole.3. Drill the four 7/32” screw holes for the four mounting studs of the Bezel plate.4. Attach and secure the Bezel plate to the front side of the mounting location using the four #10 flatwashers, #10 split lock washers, and the 10-32 hex nuts.5. Remove the Display Module from the EOI of the ASD.efesotomasyon.com -Toshiba inverter,drive,servo,plc