Taco 0015e3-2 Instruction Sheet
102-541SUPERSEDES: January 19, 2021 EFFECTIVE: August 16, 2021Plant ID No. 001-50010015e3-2 ECM High-Efficiency CirculatorDESCRIPTION:The 0015e3 is a variable speed ,high-efficiency, wet rotor circulator with an ECM, permanent magnetmotor. With 3 easy settings, its performance curves are equivalent to the versatile Taco 0015 3-speed andideal for hydronic systems zoned with circulators or zone valves. The 0015e3 reduces power consump-tion by up to 85% compared to equivalent AC permanent split capacitor circulators.APPLICATION:• Maximum operating pressure: 125 psi (8.6 bar)• Maximum water temperature: 230°F (110ºC)• Electrical specifications:Voltage: 110-120V, 50/60 Hz, single phaseMaximum operating power: 44WMaximum amp rating: 0.54• Equipped with a cast iron casing and should be used for closed loop systems only• Not suitable for open loop potable water or chilled water systems• Taco circulator pumps are for indoor use only – employer uniquement a l’interieur• Acceptable for use with water or maximum of 50% water/glycol solutionFEATURES:• Three easy settings to match system requirements - LOW, MEDIUM, HIGH• Replaces all single speed and 3-speed circulators in its class• ECM performance equivalent to the versatile Taco 0015 3-speed circulator• Multi-color LED display showing power on and error code diagnostics• Use with a Taco ZVC Zone Valve Control or SR Switching Relay for ON/OFF operation• Nut capture feature on flanges for easier fit up• Dual electrical knockouts and 6” stranded wire leads for easy wiring• Double insulated - no ground-wire required• Whisper quiet operation• BIO Barrier® protects the pump from system contaminants• SureStart ®- automatic unblocking and air purging mode• Optional 2-way universal flange model for easy fit-up to any flange orientation. See Figure 1.• Integral Flow Check (IFC® ) included - Field installed• Green Mode - active system monitoring and power optimizationWARNING: Do not use in swimming pool or spa areas. Pump has not been investigated for these applications.AVERTISSEMENT : Ne pas utiliser dans une piscine ou un spa. La pompe n'a pas été étudiée pour ces applications.CAUTION: The addition of petroleum based fluids or certain chemical additives to systems using TACO equipmentvoids the warranty. Consult factory for fluid compatibility.ATTENTION : L'ajout de liquides à base de pétrole ou de certains additifs chimiques à des systèmes utilisant unéquipement TACO annule la garantie. Consultez le fabricant pour connaître la compatibilité de liquides.CAUTION: Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to preventpump cavitation and flashing. Premature failure may result. Adjust expansion tank pressure to equal fill pressure. Alarger size expansion tank may be required.ATTENTION : Des installations à des altitudes de plus de 1600 mètres doivent présenter une pression de remplis-sage plus élevée de 20 psi au minimum afin d'éviter toute cavitation ou flashing de la pompe. Une défaillance pré-maturée peut en résulter. Réglez la pression du réservoir d'expansion de façon qu'elle soit égale à la pression deremplissage. Un réservoir d'expansion d'une taille supérieure peut être nécessaire.Instruction Sheet®INSTALLATION:Standard flange model:0015e3-2F2Optional 2-way flange model:0015e3-2F4Figure 1:®-1- |
Related manuals for Taco 0015e3-2
Taco 0015e3 Instruction Sheet
Taco 0015e3 Instruction Sheet
Taco 0012 Instruction Sheet
Taco 001-3914 Instruction Sheet
Taco 0010-MSF-IFC Instruction Sheet
Taco TacoGenie 006-CT-USK Instruction Sheet
Taco Viridian 15 Instruction Sheet
Taco X Pump Block Instruction Sheet
Taco Viridian VR1816 Instruction Sheet
Taco LoadMatch L0410-Y6CI1-FHAN Instruction Sheet
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved