4 (E) MJ620SW1123456ON ON123456SW25 SPEED ALARM lampLights when the speed of the input signal is too fast.6 Encoder signal input connectorThis connector is used for encoder signal input.7 Output connectorThis connector is used to input power and to output each signal.3-2. SwitchesThe MJ620 has two switches, mode switches 1 and 2, which can be operated from the top ofthe unit.The mode switches are used to set the reference point, number of divisions (number ofinterpolations), and other functions.MODE switches 1-1 and 1-2 (reference point position 1 and 2 switches)This interpolator outputs a reference point that is in sync with the A/B phases. However, itis necessary to set the phase relationship between the reference point gate signal that is inputand the encoder signal beforehand.The phase relationship is set by these two switches. For more information, see the section“3-4. Using the reference point.”MODE switch 1-3 (reference point adjustment mode switch)This switch is used to switch between interpolation mode and reference point adjustmentmode. Normally, this switch is set to OFF. For more information, see the section “3-4. Usingthe reference point.”MODE switch 1-4 (reference point mode switch)This switch is used to change the output width of the reference point. For more information,see the section “3-4-2. Setting the reference point output signal width.” |