Siemens SL2MTSW A Series Installation Instructions Manual
Also see for SL2 Series: Installation instructionsInstallation instructionsInstallation instructionsInstallation instructionsInstallation instructions
INSTALLATION INSTRUCTIONSSL2 SERIES MULTI-TONE STROBE, COLORWITH PRE-WIRE/PRE-TEST (WALL MOUNT)Siemens Industry, Inc.Building Technologies Division2 Gatehall DriveParsippany, NJ 07054PN P85862-003ASiemens Canada LimitedBuilding Technologies Division1577 North Service Road EastOakville, Ontario, L6H 0H6CanadaPN P85862-003A Page 1IMPORTANT: All audible and visual signaling appliances must be installed in accordance with all applicable national and local fire alarmcodes and any other required regulatory agencies.The Siemens SL2 series Multi-Tone Strobe appliances are designed for easy installation with a pre-wire capable mounting plate. SL2 Multi-Tone Strobe (Amber, Blue, or Red) is UL Listed under Standard 1971, UL 1638 for Visual Signaling Devices and Standard 464 for AudibleSignaling Devices. The SL2 Multi-Tone is also ULC Listed under Standard CAN/ULC-S526-16 for Visual Signaling Devices and underStandard CAN/ULC-S525-16 for Audible Signaling Devices for Fire Alarm Systems. These models are listed for indoor use only, and forwall mount only when used with the backboxes specified in these instructions (see mounting options).SL2MTS Multi-Tone appliances can be field set to produce any one of eight commonly used alarm tones. Sound output can be field set toprovide either HIGH (HI) dBA or STANDARD (STD) dBA sound output level. SL2MTS Multi-Tone appliances are designed for use witheither filtered or unfiltered Full-Wave-Rectified (FWR) input voltage. All inputs are polarized for compatibility with standard reverse polaritysupervision of circuit wiring by a Fire Alarm Panel (FACP). The horn portion of the SL2MTS appliance can be field set to provide asynchronized code 3 horn when used in conjunction with the DSC Sync Module or Siemens power supply.The Siemens SL2 strobe meets NFPA 2016 20 millisecond light pulse duration code requirements. In addition, the Siemens SL2 productline has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to becompatible with Siemens ST Strobe based products including the SL, ST, SE, SEH, SET, S-HQ, STH, AS, CH, HS, MTH and Z series. Themaximum number of SL2 devices per NAC is determined by dividing the maximum current rating of the FACP NAC by the total currentrating of one SL2 device, with a maximum of 105 SL2 devices per NAC. Refer to FACP installation instructions and relevant compatibilityguides for more detail. The Siemens SL2 Series may be installed in the same notification zone and field of view with any Siemens ST, SL,and Z series Strobe based product.Siemens SL2 Multi-Candela Multi-Tone-Strobes can provide a synchronized strobe appliance when used in conjunction with an FACP thatincorporates the Siemens sync protocol, a Sync Module (DSC), or the Siemens Power Supply.CAUTION: Do not change factory applied finishes. “DO NOT PAINT”.ATTENTION: Ne pas modifiez les finitions appliquées en usine. “NE PAS PEINTURER”IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH ANY OF THE FOLLOWINGINSTRUCTIONS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS INAN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH.SPECIFICATIONS:Table 1: SpecificationsModels* SL2MTSWx-A(Amber), SL2MTSWx-NB(Blue), SL2MTSWx-NR(Red)Agency Strobe: UL1638, UL1971,CAN/ULC-S526-16Multi-Tone: UL464, CAN/ULC-S525-16Input Voltage DC or FWR, 24V Regulated, 16 to 33V (All models)Volume Setting STD (standard) or HI (high) (selectable via DIP switch SW1 POS1)Tone Setting Eight (8) selectable tones (via DIP switch SW1, POS 2,3,4)Strobe Light Output Six (6) Candela settings. See Table 2 and Figure 5. (field selectable)NAC Characteristics Max. line resistance: 35ΩEnvironmental Indoor Use Only. 0° C – 50° C (32° F – 122° F) 93% R.H.* note: x = grille color (W or R); N = no letteringTable 2: SL2 Strobe Candela and Current Ratings (AMPS) **Regulated 24DC (16-33VDC) Regulated 24FWR (16-33VRMS)Amber Candela 15cd 30cd 75cd 110cd 135cd 185cdBlue or Red Candela 5cd 10cd 20cd 30cd 40 cd 50cdDC 0.022 0.030 0.060 0.086 0.125 0.185FWR 0.036 0.050 0.092 0.142 0.196 0.274** Setting will determine the current draw of the product.NOTES:1. The strobe will produce 1 flash per second over the "Regulated Voltage" range.2. Strobe is not designed to be used on coded systems in which the applied voltage is cycled on and off.3. The maximum number of SL2 strobes on a single notification appliance circuit shall not exceed 105.4. These appliances are UL Listed as “Regulated”. They are intended to be used with FACPs whose notification circuits are UL Listedas “Regulated.”5. The effect of shipping and storage temperatures shall not adversely affect the performance of the appliance when it is stored in theoriginal cartons and not subjected to misuse or abuse.When calculating the total currents: Use Table 2, 3 to determine the highest value of “RMS Current” for an individual appliance, thenmultiply these values by the total number of appliances; be sure to add the currents for any other appliances powered by the same sourceand include any required safety factors. Make sure that the total RMS current required required by all appliances that are connected to thesystem’s PRIMARY and SECONDARY power sources, NAC circuits, DSC Sync Modules or Siemens Power Supplies does not exceed thepower sources’ rated capacity or the current ratings of any fuses on the circuits to which these appliances are wired. Check the minimumand maximum output of the power supply and standby battery, and subtract the voltage drop from the circuit wiring resistance to determinethe applied voltage to the appliance.CAUTION: If SL2MTS Multi-Tone appliances are operated within 15 inches of a person’s ear, they can produce a soundpressure level that exceeds the maximum 120 dBA permitted by ADA and OSHA rules. Exposure to such sound levels canresult in damage to a person’s hearing.ATTENTION: Si les appareils SL2MTS Multi-Tone sont utilisés à moins de 15 pouces de l’oreille d’une personne, ils peuventproduire un niveau de pression acoustique supérieur à la vitesse maximale de 120 dBA permise par les règles de l’ADA et del’OSHA. L’exposition à de tels niveaux sonores peut endommager l’ouïe d’une personne.Table 3: Current and Sound Pressure Ratings for SL2MTSW Multi-Tone AppliancesTone Volume Maximum RMS Current(AMPS)Reverberant dBA at 10ftPer UL 464Anechoic dBA at 10 ftPer CAN/ULC S525-1616-33VDC 16-33VFWR 16V 24V 33V 16V 24V 33VHorn HI 0.108 0.087 88 91 93 95 99 100STD 0.044 0.045 82 86 88 89 93 94Bell HI 0.053 0.067 80 83 87 85 89 91STD 0.024 0.028 72 76 80 77 81 84March Time HI 0.104 0.087 85 88 90 95 99 100STD 0.087 0.045 79 83 85 89 93 94Code 3 Horn HI 0.122 0.087 84 87 89 95 99 100STD 0.035 0.045 78 82 85 89 93 94Code 3 Tone HI 0.135 0.110 81 85 86 91 95 96STD 0.035 0.029 76 80 82 86 90 91Slow Whoop HI 0.098 0.092 87 90 92 95 99 100STD 0.037 0.042 80 84 87 90 94 95Siren HI 0.104 0.092 86 89 92 94 98 99STD 0.036 0.040 81 84 87 89 93 94HI/LO HI 0.057 0.063 86 88 91 89 93 94STD 0.025 0.032 80 84 86 84 88 89Table 4: ULC Directional Characteristics-3dB +/- 35 Degrees Horizontal, +/- 35 Degrees Vertical-6dB +/- 45 Degrees Horizontal, +/- 45 Degrees VerticalWIRING DIAGRAMS:Figure 1A: One circuit.SL2MTS Multi-Tone and Strobe activate in unison.Figure 1B: Two Circuits (Multi-Tone may be Coded)SL2MTS Multi-Tone and Strobe will operate independently*Refer to DSC Sync Module instruction sheet or Siemens Power Supplies for additional information.Figure 2:1. This model has in-out wiring terminals that accept two #12 to #18 American Wire Gauge (AWG) wires ateach screw terminal. Strip leads 3/8 inches and connect to screw terminals.2. Break all in-out wire runs on supervised circuits to assure integrity of circuit supervision as shown inFigure 2. The polarity shown in the wiring diagrams is for operation of the appliances. The polarity isreversed by the FACP during supervision.TO NEXTOR E.O.L.R.APPLIANCE+-FROM PRECEDING APPLIANCEFACP, POWER SUPPLYOR SYNC MODULE+-TO NEXTOR E.O.L.R.OR SYNC MODULEAPPLIANCE+-+-FROM PRECEDING APPLIANCEFACP, POWER SUPPLYFROM PRECEDING APPLIANCEFACP, POWER SUPPLYTO NEXTOR E.O.L.R.OR SYNC MODULEAPPLIANCE+-+- |
Related manuals for Siemens SL2 Series
Siemens SL2 Series Installation Instructions Manual
Siemens SL2 Series Installation Instructions Manual
Siemens SL2 Series Installation Instructions Manual
Siemens SL2 Series Installation Instructions Manual
Siemens LI L Series Installation Instructions Manual
Siemens TNKM Series Installation Instructions Manual
Siemens BD2-GK Series Installation Instructions Manual
Siemens CAB-TK Series Installation Instructions Manual
Siemens BD 2-AK 1 Series Installation Instructions Manual
Siemens LI TV-B Series Installation Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved