5.4.8.2 Diagnostics options during bootingDiagnostics while booting supplementary conditionsIn the following supplementary conditions, the diagnostics window is displayed and booting ofthe TCU is interrupted:● When the <1 / F1> function is selected during booting● When a warning message is displayed● When a fault occursYou can select functions <1 / F1> to <8 / F8> mentioned below by tapping on the Panel.Alternatively, you can do this via the corresponding function keys of a connected USBkeyboard.Using the <1 / F1> function7hin Client BootloaderBoot ProgressBIOS VersionMAC AddressHardware-IDNetwork linkBoot from USBIP AddressNetmaskDHCP ServerBoot ServerImage MetadataImage VersionLinux Image (linux.bin)Image KindBooting<1/F1> protocol <2/F2> Readme_OSS <7/F7> continue <8/F8> rebootV05.00.45.00V15.00.00.0008:06:00:F1:F7:F87.9.2.01000MB, full duplexno device found192.168.214.14255.255.255.0192.168.214.1192.168.214.171 bytesV05.00.46.003295436 bytesfrom boot serverreadyKey / text MeaningF1 protocol Display detailed informationF2 Readme_OSS Details of the Open Source licensesF7 continue Continue booting of the TCUF8 reboot Restart the TCUNetworking5.4 Service and diagnosticsOperator panel front: OP 012Manual, 05/2019, A5E36371591B AB 73