Testing mechanical ambient conditionsThe table below provides information on the type and scope of tests for mechanical ambientconditions.Tested for Test standard CommentsVibration Vibration test according toDIN EN 60068, part 2–6 (si‐nusoidal)Type of vibration:Frequency cycles at a rate of change of 1 octave/minute.5 Hz ≤ f ≤ 8.4 Hz, constant amplitude 3.5 mm8.4 Hz ≤ f ≤ 200 Hz, constant acceleration 1 gVibration duration:10 frequency cycles per axis in each of the three mutually vertical axesShock Shock test according to DINEN 60068, part 2 –27Type of shock: Half-waveSeverity of shock:Peak value 15 g, duration 11 msDirection of shock:3 shocks in ± direction of axis in each of the three axes vertical to eachotherClimatic ambient conditionsThe following table shows the climatic ambient conditions for operation of the device.Ambient conditions Permissible range CommentsTemperature:Vertical mountingMounting at an angleFrom 0 to 45° C (horizontal)From 0 to 40° C (horizontal) Slope angle max. 35°Relative humidity 10% to 90%, without condensationAtmospheric pressure 1080 to 795 hPa Corresponds to an elevation of -1000 m to2000 mPollutant concentration SO2: < 0.5 vpm;Relative humidity < 60%, no condensationTest: 10 cm3/m3; 21 daysH2S: < 0.1 vpm;Relative humidity < 60%, no condensationTest: 1 cm3/m3; 21 daysTechnical specifications7.1 MonitorERGOline Stage 3Manual, 02/2015, 6FC5397-4FP40-0BA0 45