8 Alarms and Messages 10.048.2 Alarms in ShopMill 8 Siemens AG, 2004. All rights reserved8-412 SINUMERIK 840D/840Di/810D Operation/Programming ShopMill (BAS) – 10.04 Edition112502 Not enough memoryProgram aborted in line %1Explanation %1 = Line numberProgram contains too many program blocksResponse Alarm displayProgram not loadedRemedy Modify program in operating area PROGRAMS CNC-ISO operatorinterface.112503 ShopMill XXXXExplanation A system error has occurred.Response Alarm displayRemedy Please note the error text and contact the Siemens A&D MC Hotline.112504 File does not exist or is incorrect: %1Explanation %1 = Name of file/contourProgram cannot interpret a program block with contour programming.Contour does not exist in directory.Response Alarm displayNC Start disableRemedy Load contour in directory.112505 Error while trying to interpret contour %1Explanation %1 = Name of contourContour incorrectResponse Alarm displayNC Start disableRemedy Check machining sequence of contour112506 Maximum number of contour elements exceeded %1Explanation %1 = Name of contourMax. permissible number of 50 contour elements exceeded duringinterpretation of machining sequence of a contour.Response Alarm displayRemedy Check machining sequence of contour and change if necessary.112541 Program cannot be interpretedExplanation The program cannot be interpreted as a sequential control programduring loading, as the program header is missing.Response Alarm displayNC Start disableRemedy -