● This data is lost when the SIMOTION D4x5‑2 is switched off.● The "volatile SIMOTION data" area contains the following data:– SIMOTION Kernel (D4x5‑2 firmware)– Technology packages (TP)– User data (programs, configuration data, parameter settings)5200LFURPHPRU\FDUG&RPSDFW)ODVKFDUG0HPRU\FDUG5$0ORDGPHPRU\ &XUUHQW5$0ZRUNLQJPHPRU\1H[W7DUJHWGHYLFH &RQILJGDWDGXULQJ5816\VWHPYDULDEOHV&RS\5$0WR520'RZQORDG8SORDG72UHVWDUWRULPPHGLDWHO\&RS\FXUUHQWGDWDWR5$0QRV\VWHPYDULDEOHV&RPPLVVLRQLQJFigure 5-3 Configuration data and system variables in the volatile memory (memory concept, principle)You can find additional information about memory management in SIMOTION in theSIMOTION Runtime Basic Functions Function Manual.5.3.3 Operations and their effect on the user memoryThe operations marked with arrows in the figures entitled "SIMOTION D4x5‑2 memory model"and "Configuration data and system variables in the volatile memory" and their effects on theuser memory are described below.SIMOTION SCOUT downloadThe following data is transferred with "Download project to target system" or "Download CPU /drive unit to target device" from the engineering system to the "volatile SIMOTION data" area:● User data (units, configuration data, parameter settings, task configuration)● Technology packages (TPs)In addition, the IP and DP parameters are saved to the "non-volatile SIMOTION data" area.The retain variables are set to their initial values, but this depends on the settings in SIMOTIONSCOUT. If the SIMOTION D4x5‑2 is switched off following the download, the volatileSIMOTION data is lost.Commissioning (hardware)5.3 User memory conceptSIMOTION D4x5-2106 Commissioning and Hardware Installation Manual, 03/2018, A5E33441636B