Planning the RF300 system4.3 Installation guidelinesSIMATIC RF30084 System Manual, 07/2016, C79000-G8976-C345-0xTransponder ANT 30 without metal ANT 30 mounted in met-al(20 mm all-round)MDS D126 1) Without metal 100 85On metal; distance 25 mm 90 75Flush-mounted in metal;distance all round 50 mm85 70MDS D160 1) Without metal 100 80On metal, distance 10 mm 85 75MDS D324 1) Without metal 100 80On metal; distance 15 mm 90 70Flush-mounted in metal;distance all round 25 mm80 65MDS D422 Without metal 100 85On metal, distance 0 mm 95 85Flush-mounted in metal;distance all round 0 mm90 80MDS D423 Without metal 100 80On metal, distance 0 mm 125 2) 115 2)Flush-mounted in metal;distance all round 0 mm80 70MDS D424 1) Without metal 100 85On metal 15 mm 95 85Flush-mounted in metal;distance all round 25 mm85 75MDS D425 Without metal 100 80On metal, distance 0 mm 95 80MDS D426 1) Without metal 100 85On metal; distance 25 mm 90 75Flush-mounted in metal;distance all round 50 mm80 70MDS D428 Without metal 100 90On metal, distance 0 mm 95 90MDS D460 1) Without metal 100 90On metal, distance 10 mm 95 85MDS D522 without metal ?? ??on metal, distance 0 mm ?? ??flush-mounted in metal;distance all round 0 mm?? ??MDS D524 1) without metal ?? ??on metal 15 mm ?? ??flush-mounted in metal;distance all round 25 mm?? ??MDS D525 without metal ?? ??on metal, distance 0 mm ?? ??