Siemens RCR100FPRF Operating Instructions Manual
1/2 Operating Instructions CB1B1433en_01 / 2013-07-05 Siemens Building TechnologiessOperating Instructions RCR100FPRFThe RCR100FPRF is a wireless "Fil Pilote" receiver which works in connection with the RDE100.1FPRF programmerfor 3 "Fil Pilote" zones.1 Indication of data transmission and operating state (LED)2 Initialization of wireless communication with transmitter (LEARN button)Do you want to pair transmitter and receiver?+–LearnModeProcedure to configure wireless transmission:The RDE100.1FPRF communicates with the RCR100FPRF at a frequency of 433 MHz.Please ensure that you have RDE100.1FPRF transmitters on hand and refer to the instructions that come with theproduct.To pair transmitter and receiver(s), proceed as follows:RCR100FPRF receiver(s) setting:1) Press and hold the LEARN button on the RCR100FPRF for at least 3 seconds and then release it.2) The red and green LEDs flash alternately to indicate that the RCR100FPRF is in learning mode.If you have several receiver(s) in the same zone:Put all receivers of the respective zone in learning mode and repeat steps 1 to 2 on each receiver.Note: All receivers of a zone must be paired at the same time!RDE100.1FPRF transmitter setting:3) On the transmitter, press + or – to select the zone that you wish to do the learning.4) Enter the parameter settings (refer to section "Do you want to change parameters?").5) Proceed to parameter P20. Press Ok and parameter P20=0 (OFF) flashes. Adjust the value by pressing + to change toP20=1 (ON), and then press Ok to confirm.6) During wireless learning, the LCD displays "rF" and "Lrn". Wait for time out, and the transmitter exits the parametersettings.Successful wireless learning:7) The green LED on the RCR100FPRF flashes for 10 minutes to indicate that it has successfully completed wirelesslearning.If you want to pair other receiver(s) for another zone:8) Repeat steps 1 to 7 and select a new zone on the transmitter in step 3.Recommendation:9) Additional test to ensure the wireless signal is fine:On the RDE100.1FPRF, select the respective zone and change the operating mode by pressing Mode.On the RCR100FPRF, the green LED should flash for 3 seconds before changing to constantly green.At the same time, observe your radiator, boiler or heater indication (if it has one) that it has changed the operatingmode.10) If step 7 or 9 is working fine, the units have been succesfully paired.Unsuccessful wireless learning:11) If the RCR100FPRF fails to receive wireless data, the red LED starts to flash **.12) Repeat steps 1 to 7 until pairing is successful.Note:Always start the receiver's learning before starting pairing with the transmitter.The units must be placed such that transmitter and received signals have limited external wireless interference.**In normal operation, if a drop in wireless communication occurs due to unforseeable noise, just leave the receiver and itwill recover automaticallyThe pairs are saved even if there is a power shut down. Communication restarts automatically after several minuteswithout any action by the user. |
Related manuals for Siemens RCR100FPRF
Siemens RK 761 Operating Instructions Manual
Siemens SENTRON VL Series Operating Instructions Manual
Siemens RCR114.1 Mounting Instructions
Siemens RCR114.1 Quick Start Manual
Siemens RDE-MZ6 Manual
Siemens RXZ90.1 Manual
Siemens SICAM FCM Manual
Siemens DESIGO RXZ90.1 Manual
Siemens easyTek User Manual
Siemens WTX16.GSM Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved