Siemens IMKW6-10 Installation Instruction
Building TechnologiesFire Safety & Security ProductsIMKW6-10Wireless Magnet Contact (EN)Kabelloser Magnetkontakt (DE)Contact aimant sans fil (FR)Contacto magnético inalámbrico (ES)Contatto magnetico via radio (IT)Contacto magnético sem fios (PT)Trådløs magnetkontakt (NO)Draadloos magneetcontact (NL)Bezdrátový magnetický kontakt (CZ)Trådlös magnetkontakt (SV)STEP: 009914_j_--_--Edition: Dec-14CADIM: A5Q00053228P/N 7121407 Rev. E11xa2 31xb 2xc 2xc 1xd 2xd 2xe4 5 67English Installation InstructionBefore starting to install and work with this device, please read the SafetyInstructionsScope of delivery (fig.1): IMKW6-10 Wireless Magnet Contact + battery 3.6V ½ AA (a) Magnet unit (b) Screws: for detector (c), for magnet (d) Plugs (e) Jumper: for disabling the back tamper switchInstallationRemoving the front cover (Fig. 2-3) Insert a screwdriver in the slot of the snap release and push gently, until thefront cover is disengaged and you hear the opening click (Fig. 2). Lift the Printed Circuit Board (Fig. 3b).Mounting the base (Fig. 4)Pay attention to the guidelines in the Installer Manual for mounting theIMKW6-10. Break out the desired holes on the base for proper installation. Mount the base to a fixed part of a door or window. Install the Printed Circuit board back into the base.Use only the screws and plugs supplied.Setting operation Mode (external contacts)The unit can be configured for connecting one or more external contacts (NC) inseries. This connection is protected by End Of Line 8.2k Ohm series resistor. Theexternal wiring can be up to 15 m (certified up to 3 m).There are 3 operation modes for the IMKW6-10. The unit learns the mode ofoperation during power-up (insertion of the battery).Mode Setting at power-upExternal Contact Internal ContactInternal contact only open closeExternal contact only Close with 8.2k EOL openInternal and external Close with 8.2k EOL closeDisable back tamper switchThe back tamper of the unit can be deactivated by inserting a jumper (Fig.3a).When the bypass jumper is set, the unit complies with EN50131 securitygrade 1. When the jumper is NOT set, the unit complies with EN50131security grade 2.Mounting the magnet (Fig. 5) Mount the magnet on the moveable part of a door or window, alignedwith the markings on the base of the detector.Installing the battery (Fig. 6-7)Risk of explosion if battery is replaced by an incorrect type. Use onlybatteries delivered by the supplier. Insert the battery according polarity (-) (+) (Fig. 6). Place the cover by inserting back in the appropriate closing pin. Screw in the retaining screw (Fig. 7).EnrolmentTo enrol the IMKW6-10 on the SiWay panel/gateway, please follow theinstructions of the corresponding installation/configuration manual.TestingAlarm transmission test Select the “Walk Test Mode” in the control panel as described in theinstallation/configuration manual in order to avoid a real alarmtransmission. Remove the magnet:The control panel will indicate each alarm transmission received. Replace the magnet:The alarm message disappears.Maintenance and ServiceCheck the detector regularly (at least once a year) to ensure that it isfunctioning correctly (by carrying out a walk test), that it is free of dirt, andthat it is securely attached. If necessary, clean and /or secure the detector.Technical DataData Protocol SiWayWireless – range up to 300 m at open spaceFrequency band 868 MHzIdentification Unique ID serial number – 24 bitEvent Transmission Alarm, Tamper, Supervision,Low Bat (at 2.4 V)Supervision Timing 6~7 minutes (random)Detection Method Internal Reed Switch and External contactsOpen/close distances (Fig. 5a)* Not tested by TeleficationClose OpenWood / Plastic <17 mm >20 mmMetal (Iron)* <6 mm >10 mmMetal (Aluminium)* <9 mm >13 mmConcrete* <15 mm >20 mmBattery Lithium. 3.6 V Type: XL-050F, Size: 1/2AALow battery threshold 2.4 VEOL resistor 8.2kPower Consumption Standby ~5 ATransmission ~16 mADimensions 87 x 35 x 25 mmWeight (inc. battery) ~40 gEnvironmental conditions:Operation temperature -10 to +50 °CStorage temperature -20 to +60 °CHumidity (EN60721) < 85% r.h., non condensingHousing protection EN60529,EN50102 IP41 / IK02Siemens Security Products hereby declares that this product is in compliance with theessential requirements and other relevant provisions of Directive 1999/5/EC on Radio andTelecommunications Terminal Equipment (R&TTE) and 2004/108/EC on ElectromagneticCompatibility (EMC).The EC Declaration of Conformity is available from your Siemens sales office or:Siemens AB, Security Products, Englundavägen 7, SE-171 24 Solna, SwedenEN 50130-4:2011, EN 50130-5: 2011, EN 50131-2-6:2008,EN 50131-5-3:2005+A1:2008 and R&TTEEN50131-2-6, Security Grade 2, Environmental Class II certified by:For more detailed instruction please refer to the manuals of the respective control panel orgateway.ab |
Related manuals for Siemens IMKW6-10
Siemens WAC 12 Installation Instructions Manual
Siemens HMS-S Installation Instructions Manual
Siemens HFPO-11 Installation Instructions Manual
Siemens FS-RD2 Installation Instructions Manual
Siemens TZC-8B Installation Instructions Manual
Siemens NCC-G16 Installation Instructions Manual
Siemens SIPASS SK5 Installation Note
Siemens FDAI91 Installation Manual
Siemens FDAI92-Ex Installation Manual
Siemens FDM231-RP Installation Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved