Operating Manual - Elevator Door Operation AT1849Additional buttons are “Select profile” and “Movement instructions”Illustration 15 Illustration 16Via the “Select profile” window an appropriate profile (1 – 6) can be selected and activated. Theprofiles are stored on the control unit AT18.Via the “Movement instructions” window the input signals of the AT18 can be simulated and theelevator door moved according to the push buttons.The clicking of a movement cycle value on the left of the editor menu (illustration 14) results inthis value being marked on the right in the illustrated movement cycle. Likewise the clicking of anincline or of another movement value in the movement cycle diagram results in the marking of thevalue belonging to it in the parameter list and therefore can easily be found.The changing of a value directly influences the presented form of the movement cycle. As an aid,attention is drawn to the setting limits of the current parameters in the top right window, as well asto their exceeding.The newly set parameters is transferred to the control unit AT18 by pressing the “Store parameterin AT” button.Going out of the movement cycle editor takes place via the “Main menu” button.WARNINGIn order for the closing speed and nudge speed to be limited depending on the door weight, it isimperative that a new teach-in drive (start with button S5000) be made after taking over anotherprofile.