Siemens 5WG1 141-1AB31 Operating And Mounting Instructions Manual
A5E03804200A DS02 Seite 1 von 3 page 1 of 3Gamma instabusKNX/DALI Gateway Twin N 141/315WG1 141-1AB31Bedien- und MontageanleitungOperating and Mounting InstructionsStand / Issued: 04/2013PEL+-PEL+-PEL+--NPEAC 230VL PEDALI ECG 1..64+-Leuchtstofflampe/LEDfluorescent lamp/LED+bus coupling unitVersorgungsupplyAC 230 VKNXNLDALINBusankopplerDALI EVGPEL+-PEL+-PEL+-NPEDALI ECG 64+-VersorgungsupplyAC 230 VDALIDALI EVGLeuchtstofflampefluorescent lampN 141/31KNX/DALI Gateway TwinDALI AktorenDALI actuators+-ABDALI TastereingangDALI push button interfac e+-PräsenzmelderPresenc e detec torDALI SensorenDALI sensors+-Bild / Figure 1DProdukt- und FunktionsbeschreibungDas KNX/DALI Gateway Twin N 141/31 ist ein KNX-Gerät mitzwei unabhängigen DALI-Schnittstellen, an die pro Kanal bis zu64 DALI-Aktoren (z.B. EVG mit DALI-Schnittstelle) und DALI-Sensoren (z.B. DALI-Tasterschnittstelle, Präsenzmelder) an-schließbar sind.DALI (Digital Addressable Lighting Interface) ist eine bidirektio-nale Kommunikations-Schnittstelle nach IEC 62386-101, derenSpezifikation von Herstellern für elektronische Vorschaltgerätefestgelegt wurde. Sie ermöglicht nicht nur das Empfangen vonz.B. Schalt- und Dimmbefehlen, sondern auch das Senden vonStatus-Information, wie z.B. den Ausfall eines Leuchtmittels oderdie Meldung eines erkannten Fehlers im Vorschaltgerät. DasKNX / DALI Gateway Twin N 141/31 ermöglicht die Kommunika-tion mit bis zu 64 DALI-Aktoren pro Kanal. Diese können inGruppen geschaltet und gedimmt werden. Es ermöglicht außer-dem das Erfassen und Übertragen von DALI-Status- und Fehler-meldungen. Den einzelnen DALI-EVG werden bei der Inbetrieb-nahme mit der ETS (Engineering Tool Software) ein individuellerName, eine Gruppe, Parameter und Szenen zugewiesen. DieZuweisung der DALI-Sensoren zu den Gruppen erfolgt ebenfallsin der ETS (siehe hierzu die Applikationsprogrammbeschrei-bung).Das integrierte Netzgerät dient zur Versorgung der Gateway-Elektronik und zur Erzeugung der DALI-Busspannung. Es ermög-licht den Betrieb des Gateways und ein direktes Schalten undDimmen aller über die DALI-Schnittstelle angesteuerten DALIEVG auch dann, wenn das Gateway noch nicht mit der ETS inBetrieb genommen wurde oder wenn die Kommunikation überKNX unterbrochen ist. Hierzu besitzt das Gerät auf der Frontseiteeinen Taster (Bild 2, A3) zur De-/Aktivierung des „Direktbetriebs“.Wird der Taster zum ersten Mal lange gedrückt, so wird in derAnzeige (A5) der Direktbetrieb durch „d“ angezeigt. Dann wer-den alle über den jeweiligen Kanal A bzw. B über die DALI-Busleitung angesteuerten Leuchten über das Tasterpaar (A7bzw. A8) gemeinsam ein-/ausgeschaltet (kurzer Tastendruck)bzw. gedimmt (langer Tastendruck). Über die LED (A4) wird derSchaltzustand der angeschlossenen Leuchten angezeigt. Wirdder Taster „Direktbetrieb“ zum zweiten Mal lang gedrückt, so er-lischt in der Anzeige das „d“ und der N 141/31 ist wieder im Bus-betrieb (Anzeige b) bzw. im Standalone-Betrieb, falls die KNX-Kommunikation nicht zur Verfügung steht.Das Gerät verfügt über eine Fremdspannungserkennung wäh-rend der Initialisierung, welche erkennt, ob fälschlicherweise anden DALI-Anschlussklemmen Spannung angelegt ist.Die DALI-Spannungsversorgung versorgt sowohl EVG als Senso-ren, wobei auf die maximal zulässige Stromaufnahme aller an-geschlossenen DALI-Geräte zu achten ist.Weitere Informationenhttp://www.siemens.de/gamma-tdAnschlussbeispielsiehe Bild 1Technische DatenSpannungsversorgung• KNX Busspannung: erfolgt über die Buslinie• KNX Busstrom: 5 mA• Elektronik und DALI-Schnittstelle:- integriertes Netzgerät für• AC 110-240 V, 50-60 Hz• DC 120-240V- Leistungsaufnahme: max. 11 WEin-/ Ausgänge• Netzanschluss: 3-polig (L, N, Erde)• DALI-Schnittstelle nach IEC 62386-101:- max. 64 DALI-EVG pro Kanal (je max. 2mA)mit > 8kOhm Eingangsimpedanz- max. Anzahl von Sensoren pro Kanal abhängig von derStromaufnahme der Sensoren (typ. 10 mit je ca. 6mA)- DALI-Spannungsversorgung pro Kanal:- ca. DC 19 V, potentialfrei, kurzschlussfest- max. Strom: Imax = 250 mA- max. garantierter Strom: Inmax = 190 mAAnschlüsse• Steckklemmen für Netzspannung und DALI-Schnittstelle, Ab-isolierlänge 10 ... 11 mm (siehe Prägung am Gerät)• Es sind folgende Leiterquerschnitte zulässig:- 0,5 ... 2,5 mm2 eindrähtig- 0,5 ... 2,5 mm2 mehrdrähtig- 0,5 ... 2,5 mm² feindrähtig unbehandelt- AWG 20 (0,75 mm²) – AWG 12 (3,3 mm²) solid,stranded• Die Netzzuleitung zum N 141/31 ist mit einem Leitungs-schutzschalter der Charakteristik B oder C für einen max.Nennstrom von 6 A abzusichern!• KNX Bus: BusklemmeMechanische Daten• Abmessungen: Reiheneinbaugerät im N-Maß,Breite: 4 TE (1 TE = 18 mm)• Gewicht: ca. 180 gElektrische Sicherheit• Schutzart (nach IEC 60529): IP 20Umweltbedingungen• Umgebungstemperatur im Betrieb: - 5 ... + 45 °C• Lagertemperatur: - 25 ... + 70 °CPrüfzeichenKNX EIBGBProduct and Applications DescriptionThe KNX/DALI Gateway Twin N 141/31 is a KNX device with twoindependent DALI interfaces. It can be connected to up to 64DALI actuators (e.g. ECG with DALI interface) and DALI sensors(e.g. DALI key interface, presence detectors) per channel.DALI (Digital Addressable Lighting Interface) is a bidirectionalcommunications interface to IEC 62386-101, whosespecification was chosen by manufacturers for electronicballasts. It not only receives, for example, switching anddimming commands, but also transmits status information suchas failure of an illuminant or reporting of a detected error in theballast. The KNX/DALI Gateway Twin N 141/31 communicateswith up to 64 DALI actuators per channel. These can beconnected and dimmed in groups. It also records and transfersDALI status and error messages. An individual name, a group,parameter and scenes are assigned to individual DALI ECGduring commissioning with the ETS (Engineering ToolSoftware). DALI sensors are also assigned to groups in the ETS(for this, go to the application program description).The integrated power supply unit supplies the gatewayelectronics and generates the DALI bus voltage. It facilitatesoperation of the gateway and direct switching and dimming ofall DALI ECG's controlled via the DALI interface, even if thegateway has still not been operated with the ETS or ifcommuncation via KNX is interrupted. For this, the device has akey (figure 2, A3) on the front to disable or enable "DirectMode". If the key is first held down, then the display (A5) indi-cates direct mode by "d". Then, all lights are switched on/off (tapthe key) or dimmed (hold the key down) together via the keypair (A7 and A8) and controlled via the DALI bus line via therespective channel A or B. The LED (A4) indicates the switchedstatus of the connected lights. If the "Direct Mode" key is helddown for a second time, then the "d" in the display goes out andthe N 141/31 is again in bus mode [display "b"] or in standalonemode, if KNX communication is unavailable.The device has a voltage detector during initialisation, whichdetected whether a voltage has been applied to the DALIterminals incorrectly.The DALI power supply feeds both ECG and sensors; verify thatthe maximum permissible current drain by all connected DALIdevices is not exceeded.Additional Informationhttp://www.siemens.com/gamma-tdExample of Operationsee figure 1Technical SpecificationsPower supply• KNX bus voltage: carried out via the bus line• KNX bus current: 5 mA• Electronics and DALI interface:- Integrated power supply for• AC 110-240 V, 50-60 Hz• DC 120-240V- Power consumption: max. 11 WInputs/outputs• Mains connection: 3-pole (L, N, ground)• DALI interface (according to IEC 60929):- max. 64 DALI devices per channel (each max. 2 mA)with > 8 kOhm input impedance- max. amount of sensors per channel depends on currentconsumption of sensors (typ. 10 with 6 mA each)- DALI power supply per channel:- approx. DC 19 V, floating, short-circuit-proof- max. current Imax = 250 mA- max. guaranteed current: Inmax = 190 mAConnections• Plug-in terminals for mains voltage and DALI interface, insu-lation strip length 10 ... 11 mm• The following conductor cross-sections are permitted:- 0.5 ... 2.5 mm2 single-core- 0.5 ... 2.5 mm2 stranded multi-core- 0.5 ... 2.5 mm² finely stranded, untreated- AWG 20 (0.75 mm²) – AWG 12 (3.3 mm²) solid,stranded• The supply cable to the N 141/31 must be fused with a cir-cuit-breaker of characteristic B or C for a max. nominal cur-rent of 6 A!• KNX bus: bus terminalMechanical data• Dimensions: device for DIN rail mounting in N-system dimen-sions, width: 4 module units (1 module unit = 18 mm)• Weight: approx. 180 gElectrical safety• Protection type (in accordance with EN 60529): IP 20Environmental conditions• Ambient operating temperature: - 5 ... + 45 °C• Storage temperature: - 25 ... + 70 °CMarkingsKNX EIB |
Related manuals for Siemens 5WG1 141-1AB31
Siemens GAMMA 5WG1 143-1AB01 Operating And Mounting Instructions Manual
Siemens SIMATIC FDE Operating Instructions Manual
Siemens SIMATIC IOT2050 Operating Instructions Manual
Siemens IE/PB LINK PN IO Operating Instructions Manual
Siemens SIMATIC PN/M-Bus LINK Operating Instructions Manual
Siemens SIMATIC PN/J1939 LINK Operating Instructions Manual
Siemens Sinamics Connect Series Operating Instructions Manual
Siemens WTT563 Series Operating And Installation Instructions
Siemens WTT568 Series Operating And Installation Instructions
Siemens VNT Installation Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved