ENGLISH18 610.40 700.21 Siemens AGPower plug1. Use plug size 0.5 / 1 or 1.5.2. Assign the plugs according to figure Fig. 5 Connect the PE conductor.3. Connect the brake via Fig. 5 the power plug. The polarity must be carefully observed.Signal plug for the encoder system and temperature sensor.1. Use an appropriate plug.2. Assign the plugs according to Fig. 5.P Power plug S Signal plugFig. 6 Degree of rotation of plugsA suitable socket plug may be used for twisting the right-angle plug. Unscrew to open thesocket plug completely and avoid any damage to the pin contacts.Maximum permissible twisting moments M maxWARNINGImproper change of the plug output direction leads to damage tothe connecting cables.Do not exceed the permissible twisting moments as per Fig. 6.A maximum of ten changes to the plug output direction arepermissible up to the stop with the attached, matching, matingplug.Plug Motor Plug size M maxPower plug1FK701. 0.5 M max = 5 Nm1FK702. - 1FK7100 1 M max = 12 Nm1FK7101 - 1FK7105 1.5 M max = 20 NmSignal plug 1FK7. M max = 12 Nm90°180°270°270°SP