35 EOthersFunction Command Direction Parameter Reply Control/Response contentsRESOLUTION CHECK PXCK R - Returns current resolution in the form of hhh, vvv.MUTE MUTE WR 0-1 0-1 0: OFF, 1: ONINFORMATION MODEL INF1 R ValueSERIAL NO SRNO R ValueTEMPERATURE SENSOR DSTA R 0 Internal temperature normal1 Internal temperature abnormal has occurred and the monitor is in standby mode2 Internal temperature abnormal occurred (To delete the information of temperatureabnormal, turn off the main power.)3 Internal temperature abnormal has occurred and backlight brightness is dimmed4 Temperature sensor abnormalTEMPERATURE ACQUISITION ERRT R Value Returns the temperature at the temperature sensors.Indicates a temperature sensor abnormality when “126” is returned.CAUSE OF LAST STANDBY MODE STCA W 0 InitializationR 0 No detectable error has occurred1 Standby mode by POWER button2 Main power off by the main power switch3 Standby mode by RS-232C or LAN4 Input signal waiting mode by No Signal6 Standby mode by abnormal temperature20 Standby mode by OFF IF NO OPERATION settingControlling the Monitor with a computer (RS-232C)