LC-42D43U3 – 4PC SetAdjust RB to the target xy values.MG5RXXXXMG5BXXXX* XXXX indicates the adjusted values between 0000 and 1023(4 digit decimal number with zero fill).* G is fixed.* The default adjustment value of RGB is the parameter valueof the WBI5 command multiplied by 2.Adjustment values are set.OKRepeat until RGBbecome the targetvalues.The adjustment value isreflected in the image.Start measurementAdjustment gradation setting (point 4 = 184 gradation adjustment*)LEV40184(WBI40736)Adjustment values are set.OKCorrection of G valueMG4GXXXXWhen G is changed at gradation 6, calculate the ratio of thechange and set the following value to XXXX: (the value set withWBI4) x 2 x (the ratio).Adjustment values are set.OKPattern displayAdjust RB to the target xy values.MG4RXXXXMG4BXXXX* XXXX indicates the adjusted values between 0000 and 1023(4 digit decimal number with zero fill).* G is fixed.* The default adjustment value of RGB is the parameter value ofthe WBI4 command multiplied by 2.Adjustment values are set.OKRepeat until RGBbecome the targetvalues.The adjustment value isreflected in the image.Adjustment gradation setting (point 3 = 128 gradation adjustment*)LEV30128(WBI30512)Adjustment values are set.OKCorrection of G valueMG3GXXXXWhen G is changed at gradation 6, calculate the ratio of thechange and set the following value to XXXX: (the value set withWBI3) x 2 x (the ratio).Adjustment values are set.OKPattern displayStart measurement