25Special functions4USER PROGRAMS3 Press the print ( ) key. The entered program number will be steadily lit and thecurrently selected parameter number for the program will blink on the right side ofthe display.4 Select the desired parameter using the right copy quantity ( ) key. The enteredparameter number will blink on the right of the display.Program Mode ParametersNo.1 Auto clear time 0 e OFF 1 e 30 sec. * 2 e 60 sec.3 e 90 sec. 4 e 120 sec.2 Preheat mode 0 e 30 sec. 1 e 60 sec. * 2 e 90 sec.3 Auto power shut- 0 e 2 min. * 1 e 5 min. 2 e 15 min.off timer 3 e 30 min. 4 e 60 min. 5 e 120 min.5 Auto power shut- 0 e OFF * 1 e ONoff modeFactory default settings are indicated with an asterisk (*).5 Press the print ( ) key. The right-hand number in the display will be steadily litand the entered value will be stored.To change the setting or to set another mode, press the clear ( ) key. Thecopier will return to step 2.6 Press the light ( ) or dark ( ) key to return to the normal copy mode.