Sealey TP955.V2 Instructions Manual
Also see for TP955.V2: Manual
1.1. ELECTRICAL SAFETY WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any otherconnectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. AResidual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual CurrentDevice (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protectedby an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.You must also read and understand the following instructions concerning electrical safety.1.1.1. The Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualifiedelectrician, using a Portable Appliance Tester (PAT), at least once a year.1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliancesand the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.and use a Portable Appliance Tester.1.1.4. Ensure that cables are always protected against short circuit and overload.1.1.5. Regularly inspect power supply cables and plugs for wear or damage and check allconnections to ensure that none is loose.1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supplyto be used and that the plug is fitted with the correct fuse - see fuse rating at right.1.1.7. DO NOT pull or carry the appliance by the power cable.1.1.8. DO NOT pull the plug from the socket by the cable.1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faultyitem repaired or replaced by a qualified electrician. When an ASTA/BS approved UK3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.Fit a new plug according to the following instructions (UK only).a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.b) Connect the BROWN live wire to the live terminal ‘L’.c) Connect the BLUE neutral wire to the neutral terminal ‘N’.d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outerinsulation extends beyond the cable restraint and that the restraint is tight.Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.To rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensurethat a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with yourelectrician.1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any applianceplugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that thecapacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the useof 2.5mm² section cable.InSTRUCTIonS FoR:DIESEL/FLUID TRANSFER pUmpMoDEL no: Tp955.V2Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructionsand properly maintained, give you years of trouble free performance.1. SAFETY INSTRUCTIONSIMPORTANT: pLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OpERATIONAL REQUIREmENTS, WARNINGS & CAUTIONS.USE THE pRODUCT CORRECTLY AND WITH CARE FOR THE pURpOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO mAY CAUSEDAmAGE AND/OR pERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. pLEASE KEEp INSTRUCTIONS SAFE FOR FUTURE USE.1.2. GENERAL SAFETY WARNING! Ensure Health & Safety, government and local authority regulations relating to the transfer of diesel are adhered to when usingthis equipment. Familiarise yourself with the application, limitations and specific hazards peculiar to the pump. WARNING! Disconnect pump from the mains power before changing accessories, servicing or performing any maintenance. DANGER: Do noT use pump for the transfer of fluid other than diesel fuel of a viscosity from 2 to 5.35 cSt at 37.8°C, with a minimumflash point (PM) of >55°C, or for any other purpose. DANGER: motor is not explosion proof and must not be used where flammable vapours may be present. Maintain pump in good condition (use authorised service agent). Drain meter and pipes before dismantling. Ensure unit is correctly calibrated before use, and after having been dismantling for maintenance. Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes. Ensure the transfer area is free of clutter and has adequate lighting. The motor is equipped with a thermal cut-out which will shut the motor off should the unit over heat.If this happens, turn the unit off and allow to cool, by which time the cut-out will automatically reset. Keep children and unauthorised persons away from the working area. Replace/repair damaged parts. Use genuine parts. Unauthorised parts aredangerous and will invalidate warranty. Do noT use the pump without the delivery nozzle attached. Do noT start or stop the pump by switching on or off at the mains power supply. Do noT operate the unit with wet hands. We recommend the use of dieselresistant gloves and goggles. Do noT use with a motor other than that built into the unit (incorrect flowpressure will distort pump accuracy). ImpORTANT: It is installer’s responsibility to ensure all supply pipes, fixtures andfittings are adequate for the safe flow of diesel fuel.FUSE RATING 13 AmpBlueNeutralWireYellow & GreenEarth WireCableRestraintBrownLiveWireOriginal Language Version TP955.V2 Issue: 2 - 23/08/10 |
Related manuals for Sealey TP955.V2
Sealey TP9424.V2 Instructions Manual
Sealey TP9424.V2 Instructions Manual
Sealey TP97 Instructions Manual
Sealey TP96 Instructions Manual
Sealey TP98 Instructions Manual
Sealey TP94 Instructions Manual
Sealey TP98 Instructions Manual
Sealey TP6818.V2 Instructions Manual
Sealey TP6801.V2 Instructions Manual
Sealey TP96.V3 Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved