Sealey SSCL1 V2 Manual
Also see for SSCL3: Quick start guideInstructionsManual
pLATFORM SCAFFOLD STANDMODEL NO: SSCL1.V2TOWER EXTENSION pACK 3 MODEL NO: SSCL3TOWER EXTENSION pACK 4 MODEL NO: SSCL4Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.IMpORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. SAFETY WARNING! Take care when using and moving scaffolding, extended ladders and other such equipment in the vicinity of powercables - risk of potentially fatal electric shock. WARNING! Ensure Health and Safety, local authority, and general workshop practice regulations are adhered to when using thisequipment.9 Familiarise yourself with the application and limitations of the scaffold, as well as the potential hazards.9 Maintain the equipment in good condition.8 DO NOT use the equipment if any parts are damaged or missing as this may cause failure and/or personal injury.9 Replace or repair damaged parts. Use genuine parts only.9 Non-authorised parts may be dangerous and will invalidate the warranty.9 Keep the work area clean, uncluttered and ensure there is adequate lighting. WARNING! Use scaffold on level and solid ground and ensure the brakes are applied and/or that the scaffold is anchored and held firmlyin place by some means. WARNING! DO NOT erect or use the scaffolding on sloping or unstable ground. WARNING! Never over-reach when on the scaffolding.9 Keep children and unauthorised persons away from the working area.8 DO NOT use the scaffolding for any purpose other than that for which it is designed.8 DO NOT allow children to climb the scaffolding.8 DO NOT use the equipment when you are tired, under the influence of alcohol, drugs or intoxicating medication.9 When not in use store in a safe, dry, childproof area.8 DO NOT use the equipment without side guardrails, knee rails and toe boards fitted. Use all the components supplied.9 When used outside, mobile scaffold towers should, wherever possible, be secured to a building or other reliable structure.9 It is good practice to tie in all scaffold towers of any height, especially when left unattended or in exposed windy conditions.Use only the recommended wall anchors.9 Beware of strong wind conditions. DO NOT erect or use a free standing tower if the wind is likely to exceed 7.7m/sec (17mph or Beaufortforce 4).9 Take care when using mobile scaffold towers in hangers or uncovered buildings as wind force may be increased due to funnelling effects.8 DO NOT climb a tower from the outside. Never climb on the horizontal or diagonal braces. You should only climb the tower on theinside using the ladder end frames.8 DO NOT lean ladders against the tower. Never use ladders or boxes to gain additional height.8 DO NOT bridge between the mobile scaffold tower and buildings.9 Stabilisers and ballast weights shall always be fitted where specified. Ballast is used at the base to stabilise towers fromoverturning. Ballast must be of solid material (i.e. NOT water or loose sand) and should be positioned so as not to overloadindividual legs. Ballast should be secured from accidental removal.9 Keep equipment clean and inspect before and after use for damage. Use serviceable equipment only. All working parts e.g.castors, adjustable legs; stabiliser clamps should be lubricated lightly with oil. Repairs should only be carried out by the supplier orother competent person approved by the supplier.9 Ensure that all personnel, tools and materials are removed from the tower prior to moving it. Only move the scaffold towermanually on a firm level surface, which is free of any obstacles.9 Only move it longitudinally or diagonally. DO NOT exceed normal walking speed. Raise the stabilisers 12mm (½”) from the ground.9 After moving re-lock the castors, check that the tower is level and ensure that the stabilisers are secure and have a firm footing.8 DO NOT exceed the safe working load of the platform. The maximum capacity of the working platform for an evenly distributed load is1.5 kN/m² (according to HD1004 – scaffold tower Class 2).8 DO NOT jump on to or off the platforms.8 DO NOT use any lifting equipment on the mobile scaffold tower.2. INTRODuCTIONSSCL1.V2: EN1004 Approved Scaffold Tower System designed to meet the UK PASMA 3T standards. Robust aluminium frame unit withdurable corrosion resistance. Heavy-duty platform with trap door for safe access to platform. SSCL1 can be used as a 3mtr or 3.8mtrworking height platform by fitting extension kit supplied with the unit. Unique design enables the unit to be quickly and easily folded down withouttools for transportation or storage. 860mm depth means unit will pass through most doorways even when fully erected. Hand rails for comfort andsafety. Four large Ø125mm castors for easy mobility.Refer toinstructionmanualOriginal Language Version© Jack Sealey Limited SSCL1.V2, SSCL3, SSCL4 | Issue:3 (3) 12/11/19 |
Related manuals for Sealey SSCL3
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved