Sealey SAC12000.V3 Quick Start Manual
Our AddressPuravent, Adremit Limited, Unit 5a, Commercial Yard,Settle, North Yorkshire, BD24 9RHGet In TouchCall: 0845 6880112Email: info@adremit.co.ukAIR CONDITIONER/DEHUMIDIFIER/HEATERMODEL NO: SAC12000.V3Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. SAFETY1.1. ELECTRICAL SAFETY WARNING! It is the user’s responsibility to check the following:Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and allelectrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electricalproducts. You may obtain an RCD by contacting your local Sealey dealer.If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable ApplianceTest) tested.Electrical safety information: it is important that the following information is read and understood.1.1.1. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.1.1.2. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.1.1.3. IMPORTANT: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with thecorrect fuse - see fuse rating in these instructions.8 DO NOT pull or carry the appliance by the power cable.8 DO NOT pull the plug from the socket by the cable.8 DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired orreplaced immediately by a qualified electrician.1.1.4. This product is fitted with a BS1363/A 13 Amp 3 pin plug.If the cable or plug is damaged during use, switch the electricity supply and remove from use.Ensure that repairs are carried out by a qualified electrician.Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.B) Connect the BROWN live wire to the live terminal ‘L’.C) Connect the BLUE neutral wire to the neutral terminal ‘N ’.Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.Sealey recommend that repairs are carried out by a qualified electrician.1.1.5. Products which require more than 13 amps are supplied without a plug. Contact a qualified electrician to ensure that a suitably ratedsupply is available. Ensure that an industrial round pin plug and socket are fitted by a qualified electrician.1.1.6. If an extension cable reel is used, ensure that it is fully unwound before connection. Use a reel that includes an RCD, an appliancewill be protected by the RCD. The cable core section is important and should be at least 1.5mm2. Ensure that the cable of the reel isappropriate for this product. We recommend the use of 2.5mm² core section cable.1.2. GENERAL SAFETY9 Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.NOTE: Appliance is filled with R290.9 Appliance shall be installed, operated and stored in a room with a floor area larger than 14.4m².8 DO NOT perforate any of the components in the refrigerant circuit. Refrigerant gas may be odourless.8 DO NOT attempt any repairs / maintenance unless suitably qualified.8 DO NOT stand or place any object closer than 500mm from the unit.8 DO NOT obstruct the air intakes or outlets of the unit, and DO NOT cover with washed clothes.8 DO NOT place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.8 DO NOT operate the unit when you are tired or under the influence of alcohol, drugs or intoxicating medication.8 DO NOT switch the unit off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.8 DO NOT remove the float lever from the water collection tank.8 DO NOT connect or disconnect the plug from the mains with wet hands.9 Always discard the water from the collection tank, DO NOT use it for any other purpose.9 Place the unit on a level and stable surface.9 To prevent water from freezing, DO NOT use the unit at ambient temperatures below 0°C.8 DO NOT use the unit outside.9 Ensure that heating appliances are not exposed to the flow of air from the unit.9 Before attempting to move the unit, empty the contents of the water tank. Use side carrying handles when moving unit.9 Switch off and disconnect unit from the mains before attempting any cleaning or other maintenance work.9 Ensure that the unit is turned off correctly when not in use, and stored in a safe, dry area, out of reach of children.Replacement fuserating:13ARefer toinstructionmanualSAC12000.V3 Issue 1 11/03/20Original Language Version© Jack Sealey LimitedDo not cover Caution:Risk of fireIndoor use only |
Related manuals for Sealey SAC12000.V3
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved