Sealey RD1500.V6 Instructions Manual
InstructIons for:ELECTRIC OIL FILLED HEATERsRD1500.V6 & RD2500.V6thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructionsand properly maintained, give you years of trouble free performance.IMPORTANT: PLEAsE READ THEsE INsTRUCTIONs CAREFULLY. NOTE THE sAFE OPERATIONAL REQUIREMENTs, WARNINGs & CAUTIONs.UsE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOsE FOR WHICH IT Is INTENDED. FAILURE TO DO sO MAY CAUsEDAMAGE OR PERsONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEAsE KEEP INsTRUCTIONs sAFE FOR FUTURE UsE.1.2. GENERAL sAFETY WARNING! Disconnect the heater from the mains power, before servicing or performing any maintenance, which must only be carriedout by an authorised service agent. report any oil leakage immediately to an authorised service agent. replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty. Ensure that the heater is used in an area larger than 4m³. Allow a few centimetres of clearance from any surface, and ensure there isgood overhead clearance for heat circulation. only use the heater in an upright position. WARNING! do not tamper with the wiring, heating element or oil. the system is a sealed unit.the breaking of any seal may be dangerous, will damage the heater and will invalidate the warranty. DO NOT use the heater for anything other than its intended purpose. It is designed for providingheat in enclosed areas, no smaller than 4m³, such as offices, homes, workshops etc. It is notsuitable for drying clothes or laundry. DO NOT place the heater close to a bath, wash basin, shower, swimming pool or any otherwater-filled area or wet surface. DO NOT get the heater wet or use in areas of high condensation. DO NOT place the heater up against any surface such as a wall, door, furniture etc. DO NOT place the heater immediately below any electrical outlet. DO NOT allow the power lead to touch the radiator surface. DO NOT cover the radiator or use it to dry laundry. DO NOT switch the heater on whilst the electrical lead is wrapped on the storage bracket. DO NOT store the electrical lead until the radiator is cold. DO NOT attempt to repair a damaged heater, contact an authorised service agent. DO NOT stand on the heater. DO NOT touch the heating elements when the heater is on as it becomes very hot.1.1. ELECTRICAL sAFETY WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets andany other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation ofappropriate safety devices. A residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We alsorecommend that a residual current Device (rcD) is used. It is particularly important to use an rcD with portable products that areplugged into a supply which is not protected by an rccB. If in any doubt consult a qualified electrician. You may obtain a residualcurrent Device by contacting your sealey dealer.You must also read and understand the following instructions concerning electrical safety.1.1.1. the Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualifiedelectrician, using a Portable Appliance tester (PAt), at least once a year.1.1.2. the Health & safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliancesand the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.and use a Portable Appliance tester.1.1.4. Ensure that cables are always protected against short circuit and overload.1.1.5. regularly inspect power supply cables and plugs for wear or damage and check allconnections to ensure that none is loose.1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supplyto be used and that the plug is fitted with the correct fuse - see fuse rating at right.1.1.7. DO NOT pull or carry the appliance by the power cable.1.1.8. DO NOT pull the plug from the socket by the cable.1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faultyitem repaired or replaced by a qualified electrician. When an AstA/Bs approved uK3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.fit a new plug according to the following instructions (uK only).a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.b) Connect the BROWN live wire to the live terminal ‘L’.c) Connect the BLUE neutral wire to the neutral terminal ‘N’.d) After wiring, check that there are no bare wires, that all wires have been correctlyconnected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.Double insulated products, which are always marked with this symbol , are fitted with live (brown) and neutral (blue) wires only.to rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensurethat a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socketwith your electrician.1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an rcD fitted is preferred since any applianceplugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that thecapacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the useof 2.5mm² section cable.1.1.12. DO NOT move the heater whilst it is ON, always disconnect from the supply and allow to cool first.FUsE RATING13 AMPBlueNeutralWireYellow & GreenEarth WireCableRestraintBrownLiveWirerD1500.V6, rD2500.V6 Issue no.1 - 26/05/09 |
Related manuals for Sealey 5024209338196
Sealey RD1500.V6 Instructions Manual
Sealey RD1500 Instructions Manual
Sealey RD1500.V2 Instructions Manual
Sealey RD800 Instructions Manual
Sealey RD800 Instructions Manual
Sealey LP1500 Instructions Manual
Sealey RD2500T Instructions Manual
Sealey IWMH1500 Instructions Manual
Sealey IWMH1500 Instructions Manual
Sealey VS230 Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved