Sealey ML1000D.V3 Instructions Manual
Also see for ML1000D.V3: Instructions
instructions fortelescopic floodlightmodel no: Ml1000d.V3thank you for purchasing a sealey product. Manufactured to a high standard, this product will, if used according to these instructions,and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. sAfetY1.1. electRicAl sAfetY WARNiNg! it is the user’s responsibility to check the following:check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs andall electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electricalproducts. You may obtain an rcd by contacting your local sealey dealer.If the floodlight is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (PortableAppliance Test) tested.electrical safety information. it is important that the following information is read and understood.1.1.1. ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.1.1.2. regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.1.1.3. important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with thecorrect fuse - see fuse rating in these instructions.8 do Not pull or carry the appliance by the power cable.8 do Not pull the plug from the socket by the cable.8 do Not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by aqualified electrician.1.1.4. This product is fitted with a BS1363/A 13 Amp 3 pin plug.if the cable or plug is damaged during use, switch the electricity supply and remove from use.Ensure that repairs are carried out by a qualified electrician.Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.b) Connect the BROWN live wire to the live terminal ‘L’.c) Connect the BLUE neutral wire to the neutral terminal ‘N’.ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.Sealey recommend that repairs are carried out by a qualified electrician.1.2. geNeRAl sAfetY WARNiNg! disconnect light from the power supply before changing accessories, servicing orperforming any maintenance.9 maintain the light in good condition. repairs must only be undertaken by a qualified electrician(use an authorised service agent).9 replace or repair damaged parts. use recommended parts only, unauthorised parts may be dangerous and will invalidate thewarranty.9 Keep a minimum distance of 1 metre from the front of light to the surface which is to be illuminated. floodlights give off intense heat.9 locate the light in an adequate area for its function, keep area clean and tidy and free from unrelated materials.9 if using an extension lead, the cable must be fully unwound from the drum.9 the lights are weather proof and may be used outdoors. ensure any extensions and plugs are weatherproof.9 if using a tripod, ensure that the legs are fully extended and are standing on a level, solid surface. ensure that the cable is safelyrouted.9 Allow power cables to run down the length of the light stand to the floor. do Not allow power cables to hang from lights above floorlevel.9 if the light uses a clamp to support it during use, ensure that the object to which it is clamped is strong enough to hold it.▲ dANgeR! do Not direct the light into a person’s eyes. these models have a very intense light output which, if incorrectly used, could causeeye damage.8 do Not touch the light when operating. Allow to cool before touching, light operates at high temperature.8 do Not handle halogen bulbs as the natural oil from hands will shorten the bulb’s life. Handle only with a soft dry cloth.8 do Not stand on the legs of a telescopic stand, and do Not hang other items, or tools, from a telescopic stand.8 do Not use the light without the front glass shield. Avoid touching the glass shield as handling may reduce its serviceable life andcause the glass to crack.8 do Not use the light without the weather seals intact.mL1000D.V3 | Issue 2(I) 18/10/16Original Language Version© Jack sealey limitedrefer toinstructionmanualrecommended fuse rating5 Amp |
Related manuals for Sealey ML1000D.V3
Sealey ML1000D.V3 Instructions Manual
Sealey ML1000D/110V.V3 Instructions Manual
Sealey ML500X.V3 Instructions Manual
Sealey ML300C.V3 Instructions Manual
Sealey ML150 Instructions Manual
Sealey ML150C Instructions Manual
Sealey ML33 Instructions Manual
Sealey ML48 Instructions Manual
Sealey MLF500 Instructions Manual
Sealey ML300C Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved