Sealey EWP050 Instructions Manual
Refer toInstructionsWear eyeprotectionWear earprotectionWear protectivegloves1. SAFETY INSTRUCTIONSINSTRUCTIONS:PETROL WATER PUMP 50mm 5.5hpM O D E L No: EWP0501.1 GENERAL SAFETY WARNING! Stop the engine and disconnect the inlet and outletpipes before performing any maintenance. WARNING! Do not operate the pump if damaged. Replace orrepair using recommended parts only. Unauthorised parts maybe dangerous and will invalidate your warranty. Use authorisedService agent only. Keep the pump in good condition. Regular maintenance willgive the best and safest performance. WARNING! DO NOT operate the pump without any waterpassing through it. To do so will damage the machine. WARNING! DO NOT operate the pump without the priming itfirst. To do so will damage the machine. WARNING! Use the pump on a flat, level surface, in ahorizontal position. Failure to do so will invalidate your warranty. Wear safety goggles, adequate protective clothing andanti-slip rubber soled footwear. Keep all persons and animals at a safe distance from theworking pump DO NOT allow children or untrained persons to operate the pump. DO NOT use the pump if the water inlet pipe is damaged.Also check that the hose is laid out straight and safely. DO NOT try to move the pump by pulling on the inlet or outletpipes. Use the machine frame. DO NOT direct the pump output towards yourself, otherpersons or animals, electrical equipment or the pump itself. DO NOT use the pump if you are tired or under the influence ofalcohol, drugs or intoxicating medication. When not in use, drain any water from the pump. Clean anddry the pump and store in a safe, dry, childproof area. DO NOT allow the pump to become frozen.1.2 ENGINE SAFETY WARNING! Check the engine oil level before each startup.Only use an SAE10W30 oil and never operate the enginewith insuffient oil. WARNING! DO NOT touch spark plug or plug lead with wet (ordry) hands whilst the engine is running - severe, potentiallyfatal, electric shock may result. For safety instructions relative to the maintenance and use ofthe petrol engine refer to the engine instruction manual. DO NOT check ignition system by removing the spark plug orspark plug lead. Use specific tester or contact service agent. DO NOT operate the pump in an enclosed area as the motorexhaust fumes are a health hazard. DO NOT use the pump with flammable, toxic or corrosive liquids. DO NOT leave the pump unattended whilst operating, and DONOT remove the fuel cap whilst the engine is running. DO NOT refuel the engine whilst it is running. Stop the engineand allow it to cool for two minutes before attempting to refuel. DO NOT refuel in a closed or poorly ventilated environment asthere is a danger of explosion or fire. Refuel out doors. DO NOT smoke or place the pump near any naked flameswhilst re-fuelling. DO NOT operate pump if there is a fuel leak. Move the unit andavoid any combustion until the leak has been fixed and themachine is dry. DO NOT start the engine if there are any flammable materialsnear the exhaust system or in the path of the exhaust gases.2. INTRODUCTION & SPECIFICATION3. FITTINGS & ACCESSORIESModel No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EWP050Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5hpMotor Type: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-stroke/UnleadedInlet Ø: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mmOutlet Ø: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mmMaximum Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600ltr/minMaximum Head: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26mtrMaximum Suction Head: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8mtrMaximum Tank Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3.6ltrNoise Rating LwA: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99dBDry Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27kgDimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .477 x 385 x 417Lay Flat Hose: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LFH1050Solid Wall Hose: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EWP050SWIntroduction:Economically designed petrol powered water pump with recoilstarting. Suitable for on site applications where mains power supply isnot available. Featuring 50mm inlet/outlet with 26mtr pumping headoffering a high flow rate up to 600ltr/min of water. Fitted on to framewith high density rubber shock absorbers, frame also aids withprotection from accidental damage.Fittings:1. Air filter cover2. Air filter3. Inlet/Outlet connector x 24. Connector locking ring x 25. Sealing washer x 26. Wire pipe clamp x 37. Petrol tank cap8. Filter basket9. Filter basket cover10. Petrol tank filter11. Spark plug spanner bar12. Spark plug spannerfig.1IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCTCORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILLINVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to theseinstructions and maintained properly, give you years of trouble free performance. DO NOT block the engine ventilation grilles. Ensure engine fuel is stored in an approved container. For long term storage ensure the fuel is drained and that thepump is adequately protected against frost. DO NOT operate the engine with either the silencer or air filterremoved. DO NOT touch the engine during or after use. To avoid burnsallow it to cool before handling.EWP050 Issue :4(L) -10/07/17© Jack Sealey Limited Original Language Version |
Related manuals for Sealey EWP050
Sealey EWP40 Instructions Manual
Sealey WPB050 Instructions Manual
Sealey SWP20 Instructions Manual
Sealey TP94 Instructions Manual
Sealey TP67 Instructions Manual
Sealey TP98 Instructions Manual
Sealey TP96 Instructions Manual
Sealey TP80 Instructions Manual
Sealey SMP60 Instructions Manual
Sealey TP97 Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved