Sealey ARD01.V2 Instructions Manual
ON-GUN DIGITAL PRESSURE REGULATOR/GAUGEMODEL NO: ARD01.V2Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to theseinstructions, and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USETHE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/ORPERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.1. SAFETY WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when usingthis equipment. WARNING! Disconnect the equipment from the air supply before changing accessories,servicing or performing any maintenance.9 Keep the equipment clean and maintain it in good condition (use an authorised service agent).9 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. WARNING! Ensure that the correct air pressure is maintained and not exceeded.9 Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that allconnections are secure.8 DO NOT direct air from the air hose at yourself, others or animals.8 DO NOT operate air tools when tired or under the influence of drugs, alcohol or intoxicating medication.9 Drain the compressor air tank and the filter bowl daily. Water in the air line will damage your equipment.9 When work is complete ensure that the air supply is turned off.2. INTRODUCTIONOn/Off button with adjustable auto-off function for extended battery life. Small and compact with composite body. Pressure can bedisplayed in psi, bar, kg/cm² or kPa.3. SPECIFICATIONModel no.: ............................................................. ARD01.V2Maximum Pressure: ........160psi/11bar/11.25kg/cm2/1100kPaMaximum Flow: ............................................ 20cfm @ 100psi4. OPERATION4.1. SETTINGSNOTE: Unless set otherwise, the gauge automatically shuts off after 60 seconds. To increase this time, see section 4.3.4.1.1. Press the on/off button once to switch the gauge on or off.4.1.2. Additionally, the on/off button may be used to alter the three function settings.4.2. CHANGING THE FUNCTION SETTING4.2.1. Ensure that the gauge is not under pressure.4.2.2. With the gauge switched on, hold the On button for about 3 seconds, until the display shows ‘---’ then release the button.4.2.3. The display will cycle between 0,1, 2, and E.[-0-] mode resets the gauge to zero.[-1-] mode resets the automatic shut-off mode.[-2-] mode resets the pressure units.[-E-] resetting is completed when “END” shows in display.4.2.4. Press the button to enter one of the modes.4.3. RESET TO ZERO4.3.1. Ensure that the gauge is not under pressure.4.3.2. Select mode 0 and the display will show 00-.4.3.5. Press the button again and the display will show 000.ARD01.V2 Issue 2 07/07/21Original Language Version© Jack Sealey LimitedRefer toinstructions |
Related manuals for Sealey ARD01.V2
Sealey ARD01 Instructions Manual
Sealey SGA3.V2 Instructions Manual
Sealey SGA4.V2 Instructions Manual
Sealey SGA4.V2 Instructions Manual
Sealey REG/MM.V2 Instructions Manual
Sealey REG/MO.V2 Instructions Manual
Sealey SA2001 Instructions Manual
Sealey SGA4 Instructions Manual
Sealey SGA30 Instructions Manual
Sealey RS22 Instructions Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved