Use the Remote Alarm buttons provided on the live screen to send alarm signals from the camera's alarm outputterminals.Required operation privilege: admin, operator1, operator2To use the remote alarm buttons, you must set in advance [ALARM OUT] to “REMOTE” and [ALARMOUT TIME] to the desired duration on the ALARM SETTINGS screen (administrator configurationmenu).1 Starting alarm signal outputClick one of the remote alarm buttons (shown in gray). The button turns orange and an alarm signal is output fromthe corresponding terminal.If the camera is connected to a buzzer or other external device, you will hear an alarm sound from that device.A : Click this to send an alarm signal from the ALARM OUT1 terminal.B : Click this to send an alarm signal from the ALARM OUT2 terminal.2 Stopping alarm signal outputThe way you stop alarm signal output differs depending on the [ALARM OUT TIME] setting on the ALARMSETTINGS screen.Automatic StopThe automatic stop method is applied if you have specified an alarm output duration in [ALARM OUT TIME].When the set output duration has elapsed, the camera stops sending the alarm signal automatically and the buttonreturns to white.Manual StopThe manual stop method is applied if you have selected “CC” in [ALARM OUT TIME].Click one of the remote alarm buttons shown in orange. Then, the camera stops outputting the signal and thebutton returns to white.Working with Live Screen 17/18