-4-Electrical Adjustmentx Auto calibration (PC)Input mode Computer mode (Input 1)Input signal 16-step gray scale computer signal1. Enter the service mode.. Select Group "260", No. "100" and set data value to "1".3. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.4. Select Group "260", No. "100" and set data value to "3".5. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.6. Select Group "260", No. "100" and set data value to "0".v Auto calibration (Component)Input mode Video mode (Input -Component)Input signal 100% color bar signal (480i)1. Enter the service mode.. Select Group "260", No. "100" and set data value to "4".3. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.4. Select Group "260", No. "100" and set data value to "5".5. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.6. Select Group "260", No. "100" and set data value to "0".b Auto calibration (Video)Input mode Video mode (Input -Composite)Input signal 16-step gray scale composite videosignal1. Enter the service mode.. Select Group "260", No. "100" and set data value to "6".3. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.4. Select Group "260", No. "100" and set data value to "0".c Auto calibration (Slot)Input mode Computer mode (Input 3)Input signal 16-step gray scale computer signalSlot board Analog RGB input board equipped1. Enter the service mode.. Select Group "260", No. "100" and set data value to "2".3. Select Group "260", No. "0" and set data value "0"to "1".The projector begins auto-calibration and then "OK"will appear on the screen.4. Select Group "260", No. "100" and set data value to "0".z Fan driving voltage adjustmentEquipment Digital voltmeterLamp mode LampsLamp control Eco11. Enter the service mode.. Change data values of each test point to adjust the fandriving voltage.Group No. Fan Connection Adjustment value250 - 1 Fan_1 K66S-1 13.8 +0 -0.1Vdc250 - 0 Fan_1 K66S-1 5.0 +0.1 -0Vdc250 - 3 Fan_ K66S- 13.8 +0 -0.1Vdc250 - 2 Fan_ K66S- 4.0 +0.1 -0Vdc250 - 5 Fan_3 K66S-3 13.8 +0 -0.1Vdc250 - 4 Fan_3 K66S-3 6.0 +0.1 -0Vdc250 - 7 Fan_4 K66S-4 13.8 +0 -0.1Vdc250 - 6 Fan_4 K66S-4 6.5 +0.1 -0Vdc250 - 9 Fan_5 K66S-5 13.8 +0 -0.1Vdc250 - 8 Fan_5 K66S-5 5.0 +0.1 -0VdcNote :Group Fan_1: FN905Group Fan_: FN904, FN906Group Fan_3: FN903, FN907, FN909Group Fan_4: FN901, FN90Group Fan_5: FN908Adjustments item no. [] to [5] are carried out at thespare parts shipment in the factory, therefore they are notrequired when the main board is replaced with new one.